SPECIFICATIONS - 9703
Gas Appliance Rating
Natural Gas
L P Gas
Freestanding / Insert
Freestanding / Insert
Input Rating (BTU/hr) 0-610m (0-2000 ft.) ALT
44,000
42,000
Orifice Size (DMS) 610m
#48 (
Front)
& #33
(Back)
#62
(Front)
& #52 (
Back)
Input Rating (Btu/hr) 610-1370 m (2000-4500 ft) ALT
41,000
39,000
Orifice Size (DMS) 1370m
#49 (
Front)
& #33
(Back)
#63 (
Front)
& #52
(
Back)
Unit Factory Equipped For 0-610m (0-2000 ft.)
Minimum Input (BTU/hr)
25,000
20,500
Manifold Pressure (in w.c./kPa)
3.5 / 0.87
11.0 / 2.74
Manifold Pressure Lo-Setting (in w.c./kPa)
1.3 / 0.42
2.7 / 0.67
Minimum Inlet Pressure (in w.c./kPa)
4.5 / 1.12
12.2 / 3.04
Maximum Inlet Pressure (in w.c. / kPa)
10.5 / 2.62
13.0 / 3.24
Shipping Weights & Dimensions
Freestanding
Fire Box Only
Shroud
Width
31.5”
28.5”
48”
Height
36”
24”
30”
Depth
24”
22.5”
3”
Weight
237 lbs.
170 lbs.
54 lbs.
Insert Units can only be installed in a masonary fireplace or
a listed wood burning “0” clearance fireplace.