Clarity CL2714 SP
INSTALLATION CLEARANCES
OPERATION OF THIS HEATER WHEN NOT CONNECTED TO A PROPERLY INSTALLED AND
MAINTAINED VENTING SYSTEM CAN RESULT IN CARBON MONOXIDE (CO) POISONING AND
POSSIBLE DEATH
MINIMUM CLEARANCES TO COMBUSTIBLES
A Unit to sidewall.
4.5” (115 mm)
B
Bottom of unit to underside of 12” mantel.
*With S.Z4991 mantel shield and 12” mantel.
**With S.Z4992 mantel sheild and 12” mantel.
***With S.Z4992 mantel sheild and 5” mantel.
48" (1219 mm)
*40" (1016 mm)
**34” (864 mm)
***32” (813 mm)
C Maximum mantel depth.
12" (305 mm)
D Minimum ceiling clearance from bottom of unit. 67.5" (1715 mm)
NOTE: CHECK LOCAL CODES FOR FLOOR REQUIREMENTS.
THIS FIREPLACE IS SUITABLE ONLY FOR INSTALLATION IN A
MASONRY OR FACTORY BUILT FIREPLACE.
*&** 12" max
*** 5" max
*40"
**34"
***32"
33"
1
1
4
"
max.
NEAREST
COMBUSTIBLE
MANTEL SHIELD
MANTEL
TRIM
12" max.
48"
33"
NEAREST
COMBUSTIBLE
MANTEL
SIDE VIEW
INSTALLATION CLEARANCE ABOVE FIREPLACE
SIDE VIEW (WITH MANTEL SHIELD)
INSTALLATION CLEARANCE ABOVE FIREPLACE