DO NOT BLOCK THE AIR DUCT OF THE INSTALLED UNIT WITH DUST ACCUMULATING 

MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC. AS IT PREVENTS AIR 

CIRCULATION IN THE ROOM.

VENTILATOR MOUNTING

1.

 Prepare core holes in the outer wall.

Prepare one or two round core holes in the outer wall depending on ventilation system configuration. To attain efficient ventilation the 
installation places of the ventilators must be located as far from each other as possible. While preparing core holes it is recommended 
to make preparations for layout of the power cable and other required cables in the wall. The hole size and minimum distance to the 
surface, e.g. wall, ceiling or window and the minimum distance between the ventilators is shown below.

min 1 m

min 1 m

min 

1 m

min 300 mm

Ø 180 mm

min 300 mm

min 300 mm

2.

 Measure the air ducts of the required length.

A

B
L

Measure the wall thickness B.
The required air duct length is calculated as L = B + A.
A means the projected part of the air duct to the outside required for 
installation of the outer ventilation grille or hood. 
A distance is stated in the installation instruction to the ventilation hood.
Cut air duct to the length L.

READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.

Содержание VENTO Eco A50-4 Pro1

Страница 1: ...Heat regeneration single room reversible ventilator USER S MANUAL EN VENTO Eco A50 4 Pro1 VENTO Eco2 A50 4 Pro1...

Страница 2: ...construction electrical and technical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection servicing maintenan...

Страница 3: ...owledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play wi...

Страница 4: ...rille type 4 white internal grille with a smooth panel Rated air capacity m3 h Air duct cross section A round Ventilator series VENTO Eco series with one ventilator and one control panel VENTO Eco2 se...

Страница 5: ...IP24 The unit design is constantly being improved thus some models may be slightly different from those described in this manual A 160 Air duct length wall thickness Outer ventilation hood Indoor unit...

Страница 6: ...l to prevent ingress of water and foreign objects into the ventilator Front part of the indoor unit Fulfils the decorative function It is a part of the indoor unit design and directs the air flow upwa...

Страница 7: ...from the room As it flows through the regenerator it heats and moisturizes the regenerator transferring heat and air moisture 70 seconds after the ceramic regenerator starts to get warmed the ventila...

Страница 8: ...ide Do not disconnect the connectors on the circuit boards in the casing 3 Connect the wires to the terminal blocks on the back side of the control panel in compliance with external wiring diagrams Fi...

Страница 9: ...ecommended to make preparations for layout of the power cable and other required cables in the wall The hole size and minimum distance to the surface e g wall ceiling or window and the minimum distanc...

Страница 10: ...rk the point 1 on the sound absorbing mat on the level of the air duct edge Cut out the excessive part of the sound absorbing mat Insert the adjusted sound absorbing roll in the air duct Do not use an...

Страница 11: ...the following criteria Always use shielded cables Wire cross section depends on the length and is selected according to the table below Cable length m Minimum wire cross section in the cable mm2 5 0 2...

Страница 12: ...n operation mode timer based ventilator operation 4 hours at the high speed or 8 hours at the low speed The display shows the parameters current speed current operation mode timer operating status ON...

Страница 13: ...w speed middle speed high speed timer Parameter setting using the or buttons 4 hours at the high speed 8 hours at the low speed turning timer off The ventilator reverts to operation with a previous sp...

Страница 14: ...ventilator will run at the permanent low speed speed setting Parameter setting using the or buttons Set the value 5 6 Return to user menu Press several times the button till the main window of the us...

Страница 15: ...Ventilation mode The ventilator runs exclusively in the supply or extract mode In case of installation of two ventilators the air flow direction depends on the external wiring refer the wiring diagra...

Страница 16: ...wn 90 days the control panel displays the filter replacement indicator Wash the filters and let those dry out completely Install the dry filters in the air duct Vacuum cleaning is allowed To reset the...

Страница 17: ...ing temperature for at least 3 4 hours TROUBLES ANDTROUBLESHOOTING Trouble Possible reasons Troubleshooting The fan does not move up during start up of the unit The control panel displays no informati...

Страница 18: ...ismantling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model mus...

Страница 19: ...ION CERTIFICATE The VENTO Eco ____________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technici...

Страница 20: ...www blaubergventilatoren de B127 1EN 01...

Отзывы: