background image

www.blaubergventilatoren.de

Solo a35/50/60 S4 Pro r (v.2)

5

150

150

v08

35

ø106

305 – 380 (700*)

TECHNICAL DATA

The temperature in the room where the indoor unit of the ventilator is installed must be in the range from +1 ˚C to +40 ˚C with relative 
humidity up to 65 % (no condensation build-up). If the conditions for using the ventilator are beyond the specified limits, turn off the 
ventilator. Provide fresh air supply through windows.
The transported air temperature must be in the range from -15 ˚C to +40 ˚C.
The ventilator is rated as a class II electric appliance.
Ingress protection rating against access to hazardous parts and water ingress is IP24.
The unit design is constantly being improved, thus some models may be different from those described in this manual.

The technical data of the specific model are indicated on the label on the ventilator casing.

The figure below shows the overall dimensions of the indoor unit of the ventilator and the minimum wall thickness sufficient for mounting 
the internal components of the ventilator inside the air duct.

Ventilator model

Dimensions [mm]

Overall 

dimension 

A

Air duct diameter 

D

Diameter of the hole in the wall for 

mounting the ventilator 

D1

Minimum possible wall 

thickness 

L

Solo A35 S4 Pro R
Solo A35 S4 Pro R V.2

150

106

120 – 125

305

Solo A50 S4 Pro R V.2

175

131

145 – 150

325

Solo A60 S4 Pro R V.2

205

156

170 – 175

355

Содержание Solo A35 S4 Pro R

Страница 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Solo A35 S4 Pro R Solo A35 S4 Pro R V 2 Solo A50 S4 Pro R V 2 Solo A60 S4 Pro R V 2...

Страница 2: ...ence and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not p...

Страница 3: ...tion The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compression of the casing Deformation of the casing may result in motor...

Страница 4: ...rated for continuous operation NAME NUMBER Solo A35 S4 Pro R Solo A35 S4 Pro RV 2 Solo A50 S4 Pro RV 2 Solo A60 S4 Pro RV 2 Ventilator 1 pc 1 pc Remote control 1 pc Plastic screwdriver 1 pc Mounting p...

Страница 5: ...nst access to hazardous parts and water ingress is IP24 The unit design is constantly being improved thus some models may be different from those described in this manual The technical data of the spe...

Страница 6: ...hrough the regenerator which gradually absorbs heat and humidity In 60 seconds as the regenerator gets warmed up the ventilator is switched to the supply mode CYCLEII Fresh intake air from outside flo...

Страница 7: ...diameter depends on the specific model of the ventilator and is indicated in the table of overall dimensions in the Technical data section D1 min 300 min 300 min 300 A A A A 2 Install the air duct int...

Страница 8: ...screw the self tapping screw from the casing and remove the front part of the indoor unit 5 Attach the mounting plate and mark holes for the dowels with a pencil or marker Drill the holes and insert t...

Страница 9: ...mains using a cord with a plug with a switch on the wire Switching from the first speed to the second is carried out only by a standard pull cord switch Speed switch speed I II ON OFF 230 V 50 Hz CONN...

Страница 10: ...button on the remote control the ventilator starts to operate at the speed at which it was switched off When switched on using buttons I or II the ventilator starts to operate at the corresponding sp...

Страница 11: ...the self tapping screw Remove the four screws retaining the indoor unit then pull it out of the air duct Consequently remove all elements of the ventilator 1 Clean the filters as they get clogged but...

Страница 12: ...the power supply line is connected correctly otherwise troubleshoot the connection error The motor is jammed the impeller blades are soiled Turn the ventilator off Troubleshoot the motor jam and the i...

Страница 13: ...suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried...

Страница 14: ...Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s man...

Страница 15: ...TION CERTIFICATE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Insta...

Страница 16: ...www blaubergventilatoren de B132EN 09...

Отзывы: