background image

www.blaubergventilatoren.de

Solo a35/50/60 S4 Pro r (v.2)

8

3. Install the assembled regenerator and the limit ring into the air 
duct.
In Solo RA1-35-9 R and Solo RA1-35-9 R V.2 models, the limit ring is 
connected to the regenerator.
In Solo RA1-50-9 R V.2 and Solo RA1-60-9 R V.2 models the limit ring 
is inserted separately.

4. Use a screwdriver to unscrew the self-tapping screw from the 
casing and remove the front part of the indoor unit.

5. Attach the mounting plate and mark holes for the dowels with a pencil or marker. Drill the holes and insert the dowels. 
Then install the mounting plate on the wall and the rear part of the indoor unit in the duct.
Fasten the rear part of the indoor unit with the screws on the mounting plate.

6. Install the front part of the indoor unit to its original position 
and fix it with a screw using a screwdriver.

7. Install the outer ventilation hood or the grille.

Содержание Solo A35 S4 Pro R

Страница 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Solo A35 S4 Pro R Solo A35 S4 Pro R V 2 Solo A50 S4 Pro R V 2 Solo A60 S4 Pro R V 2...

Страница 2: ...ence and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not p...

Страница 3: ...tion The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compression of the casing Deformation of the casing may result in motor...

Страница 4: ...rated for continuous operation NAME NUMBER Solo A35 S4 Pro R Solo A35 S4 Pro RV 2 Solo A50 S4 Pro RV 2 Solo A60 S4 Pro RV 2 Ventilator 1 pc 1 pc Remote control 1 pc Plastic screwdriver 1 pc Mounting p...

Страница 5: ...nst access to hazardous parts and water ingress is IP24 The unit design is constantly being improved thus some models may be different from those described in this manual The technical data of the spe...

Страница 6: ...hrough the regenerator which gradually absorbs heat and humidity In 60 seconds as the regenerator gets warmed up the ventilator is switched to the supply mode CYCLEII Fresh intake air from outside flo...

Страница 7: ...diameter depends on the specific model of the ventilator and is indicated in the table of overall dimensions in the Technical data section D1 min 300 min 300 min 300 A A A A 2 Install the air duct int...

Страница 8: ...screw the self tapping screw from the casing and remove the front part of the indoor unit 5 Attach the mounting plate and mark holes for the dowels with a pencil or marker Drill the holes and insert t...

Страница 9: ...mains using a cord with a plug with a switch on the wire Switching from the first speed to the second is carried out only by a standard pull cord switch Speed switch speed I II ON OFF 230 V 50 Hz CONN...

Страница 10: ...button on the remote control the ventilator starts to operate at the speed at which it was switched off When switched on using buttons I or II the ventilator starts to operate at the corresponding sp...

Страница 11: ...the self tapping screw Remove the four screws retaining the indoor unit then pull it out of the air duct Consequently remove all elements of the ventilator 1 Clean the filters as they get clogged but...

Страница 12: ...the power supply line is connected correctly otherwise troubleshoot the connection error The motor is jammed the impeller blades are soiled Turn the ventilator off Troubleshoot the motor jam and the i...

Страница 13: ...suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried...

Страница 14: ...Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s man...

Страница 15: ...TION CERTIFICATE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Insta...

Страница 16: ...www blaubergventilatoren de B132EN 09...

Отзывы: