Switching the

ventilator on/off

Setting the first (lower)

fan speed

Setting the second (higher) 

fan speed

Switching off the night

mode of the fan

Switching on the night 

mode of the fan

Switching off the humidity 

sensor

Switching on the humidity 

sensor

60%

90%

Adjust the threshold of the

humidity sensor

Controlling the Solo A35 S4 Pro R V.2, Solo A50 S4 Pro R V.2, Solo A60 S4 Pro R V.2 ventilator using the remote control

The ventilator is connected to power mains using a cord with a plug.
The functions of the remote control buttons are shown in the figure below.
The speed at which the ventilator is currently operating is indicated by a coloured LED on the front panel of the indoor unit. The first 
(lower) speed corresponds to the green colour, the second (higher) speed corresponds to the blue colour of the LED.
The passage of remote control commands is confirmed by a short-term decrease in the brightness of the LED on the front panel of the 
indoor unit.

When switched on using the 

On/Off

 button on the remote control, the ventilator starts to operate at the speed at which it was switched 

off.

When switched on using buttons 

I

 or 

II

, the ventilator starts to operate at the corresponding speed.

If the humidity sensor is switched on, then when the humidity exceeds the preset level, the ventilator switches to the second (higher) 
speed.
At high outdoor air humidity, the ventilator can switch to the second (higher) speed as a result of the humidity sensor triggering.
If such switching is undesirable, then temporarily turn off the humidity sensor using the remote control.
You can adjust the operating threshold of the humidity sensor by turning the potentiometer regulator using a special plastic screwdriver.

When turning on the night mode, the ventilator will operate at the first (lower) speed for 8 hours. At this time, the brightness of the LED 
decreases and the ventilator does not respond to speed switching and triggering of the humidity sensor. After the end of this time period, 
the ventilator will return to the previous operating mode. The night mode can be turned off at any time using the corresponding button 
on the remote control.

DO NOT USE A METAL SCREWDRIVER, KNIFE, ETC. FOR ADJUSTMENT 

OPERATIONS NOT TO DAMAGE THE CIRCUIT BOARD. 

Содержание Solo A35 S4 Pro R

Страница 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Solo A35 S4 Pro R Solo A35 S4 Pro R V 2 Solo A50 S4 Pro R V 2 Solo A60 S4 Pro R V 2...

Страница 2: ...ence and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not p...

Страница 3: ...tion The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compression of the casing Deformation of the casing may result in motor...

Страница 4: ...rated for continuous operation NAME NUMBER Solo A35 S4 Pro R Solo A35 S4 Pro RV 2 Solo A50 S4 Pro RV 2 Solo A60 S4 Pro RV 2 Ventilator 1 pc 1 pc Remote control 1 pc Plastic screwdriver 1 pc Mounting p...

Страница 5: ...nst access to hazardous parts and water ingress is IP24 The unit design is constantly being improved thus some models may be different from those described in this manual The technical data of the spe...

Страница 6: ...hrough the regenerator which gradually absorbs heat and humidity In 60 seconds as the regenerator gets warmed up the ventilator is switched to the supply mode CYCLEII Fresh intake air from outside flo...

Страница 7: ...diameter depends on the specific model of the ventilator and is indicated in the table of overall dimensions in the Technical data section D1 min 300 min 300 min 300 A A A A 2 Install the air duct int...

Страница 8: ...screw the self tapping screw from the casing and remove the front part of the indoor unit 5 Attach the mounting plate and mark holes for the dowels with a pencil or marker Drill the holes and insert t...

Страница 9: ...mains using a cord with a plug with a switch on the wire Switching from the first speed to the second is carried out only by a standard pull cord switch Speed switch speed I II ON OFF 230 V 50 Hz CONN...

Страница 10: ...button on the remote control the ventilator starts to operate at the speed at which it was switched off When switched on using buttons I or II the ventilator starts to operate at the corresponding sp...

Страница 11: ...the self tapping screw Remove the four screws retaining the indoor unit then pull it out of the air duct Consequently remove all elements of the ventilator 1 Clean the filters as they get clogged but...

Страница 12: ...the power supply line is connected correctly otherwise troubleshoot the connection error The motor is jammed the impeller blades are soiled Turn the ventilator off Troubleshoot the motor jam and the i...

Страница 13: ...suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried...

Страница 14: ...Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s man...

Страница 15: ...TION CERTIFICATE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Insta...

Страница 16: ...www blaubergventilatoren de B132EN 09...

Отзывы: