3. General Safety Rules 

 

Warning! 

Read all safety warnings and all instructions.  

Failure to follow the warnings and 

instructions may result in electric shock, fire, explosions and / or serious injuries.  
 
Only authorized and trained personnel may operate this machine. This machine is not intended for use by 
persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge. 
 
It is the responsibility of the user to analyse the surface to be treated. The surface may not contain any 
substances which could pose a fire-, explosion- or health risk when treated. The user should make a risk 
assessment on the basis of the information obtained about the surface to be treated and take proper 
precautions for the work to be performed. 
In case of any inappropriate usage, improper operation or repair, the producer shall be exempt from liability. 
 
 

3.1

 

Work area safety 

a)

 

Do not use the machine in rain, damp or wet locations. 

b)

 

Avoid dangerous environments:

 do not work in the presence of explosive atmospheres, in the 

presence of flammable liquids, gases or dust. Remove materials or debris that may be ignited by sparks. 

c)

 

Make sure there is enough ambient light on the work area. Cluttered or dark areas invite accidents. 

d)

 

Only use the machine when it is parked on a flat, horizontal surface. 

e)

 

Keep children and bystanders away while operating the machine. They are likely not to foresee the 
potential dangers of the machine. Distractions could cause you to lose control of the machine.  

f)

 

Persons who are not operating the machine must not be permitted to stay in the surrounding area of at 
least 5 meter from the machine. 

g)

 

Secure the work area around the machine in public areas providing an adequate safety distance from the 
machine. Use a red and white safety chain and danger sign to enclose the work area. 

h)

 

It is necessary to provide for an adequate air change rate L in the room if the exhaust air is returned to 
the room. Comply with the National regulations. 

i)

 

Never use the machine when the surface

 

is not clear and if there is a risk of stumbling or tripping. 

j)

 

Remove electrical cables and dust hose from the surface to be treated.  

k)

 

Make sure that there are no cables or hoses in the driving direction of the machine. 

l)

 

Make sure that there is nothing standing or situated on the surface to be treated. 

m)

 

Make sure the machine can travel over all inequalities on the surface, small inequalities like weld seams or 
(floor) joints are no barriers for the machine. 

n)

 

Never operate the machine when workplace is wet. Never stay in the rain with the machine. 

o)

 

Check if there are any obstacles that can snag the cables when the machine is moving. 

p)

 

Warning!  
Make sure that the surface to be treated does not contain dangerous materials such as: 
- combustible or explosive dusts or substances. 
- carcinogenic or pathogenic substances. 
In these cases, additional safety measures should be used. Always mind the local safety 
requirements. 

Contact your dealer for additional options. 

q)  It is necessary to provide for an adequate air change rate L in the room if the exhaust air from the dust 

collector is returned to the room. Comply with the National regulations. 

r)  Secure the work area around the machine in public areas providing an adequate safety distance from the 

machine. Use a red and white safety chain and danger sign to enclose the work area. 

 

3.2

 

Electrical safety 

a)

 

Use only extension cables for extending the main cable that are sized and marked in accordance with the 
overall power consumption of the machine. 

Do not use damaged extension cables.

 

b)

 

Electrical cables must be rolled entirely off of the reels. 

c)

 

Any damage to the electric cables and/or electrical components is not permitted. 

Содержание 854 DCS

Страница 1: ...Original instructions in English Any other language is a translation of the original instructions OPERATING INSTRUCTIONS 854 DCS VERSION 2 4 ...

Страница 2: ...on By competent person Inspection before initial operation on __________________________________________ By __________________________________________ Date of initial operation __________________________________________ Serial number Year of manufacture __________________________ _____________ ...

Страница 3: ... 9 3 8 Signs on the machine 10 4 Before operation 11 4 1 Checkpoints of electrical safety 11 4 2 Checkpoints of the machine 11 4 3 Control box 11 4 4 Transport 12 5 Operation 13 5 1 Before switch on 13 5 2 Starting stopping the machine 13 5 3 Working with the machine 13 5 4 Interrupting work 14 5 5 Emptying the dustbin 14 6 Maintenance 15 6 1 Filter replacement 16 6 2 Pulse system 17 6 3 Water sep...

Страница 4: ...sed for pathogenic or carcinogenic or asbestos substances without additional safety measures Always mind the local safety requirements Contact your dealer for additional options Do not use the machine in the presence of dangerous atmospheres The machine is designed for usage in conditions according to classification M see below Classification acc standard EN 60335 2 69 Annexe AA Class Designation ...

Страница 5: ...eparator to the pulse system The conditioned air then passes a control valve which regulates the system pressure and then builds up pressure in the pulse tank The pressurized air is used to generate a pulse of air which cleans the filters from the inside With every pulse of the pulse system dust and particles are released from the filter surface 01 Extension lead for Blastrac machine 07 Control va...

Страница 6: ...chine Use a red and white safety chain and danger sign to enclose the work area h It is necessary to provide for an adequate air change rate L in the room if the exhaust air is returned to the room Comply with the National regulations i Never use the machine when the surface is not clear and if there is a risk of stumbling or tripping j Remove electrical cables and dust hose from the surface to be...

Страница 7: ...chine pull out the main plug s If the machine is to be operated using power from a generator the generator must be operated in accordance with the current legal regulations and directives in force this applies to the protective earth conductor in particular in order to ensure that all safety devices are functioning and to eliminate possible damage to electrical components 3 3 Personal safety a Alw...

Страница 8: ... of the inlet when the machine is turned off This prevents moisture dust and other contaminants to enter the machine q If dust leaves the filter unit instead of clean air this is a sign that the filter cartridges are damaged or not fixed correctly inside the chamber Do not proceed Rectify immediately r When a filter is leaking it has to be replaced The compartment above the filters and silencer al...

Страница 9: ...from the hazardous zone and appropriate actions must be taken to prevent dust from dispersing f Always close the inlet of the dust collector using the butterfly valve when the dust hose is disconnected g Make sure the dust hoses are disconnected and put away properly before transport h The weight of the 854 DCS is 575 kg Use a crane or lift when transporting the machine use the lifting eye of the ...

Страница 10: ...r controller or associated wiring Lifting point Wear a dust mask class FFP2 or higher Hearing protection is obliged Safety glasses with lateral protection are obliged CE mark on this machine Wear protecting gloves Safety shoes obliged Consult the manual before operating the machine Name address and CE mark The machine type The net weight of the machine in kilogram The year of manufacture The seria...

Страница 11: ...2 Checkpoints of machine Safety functions and operating functions must work correct Check all screws and other fasteners for tightness No loose bolts and or nuts are permitted Check the electrical components cables and connections for wear and or damages Dust hose connection must be reliable use hose clamps and industrial tape Dust hoses must be undamaged and free of obstructions Make sure that th...

Страница 12: ...ol box door Now you can adjust the turning direction of the motors with the phase inverter switch Pressure difference gauge This gauge indicates the pressure difference between the clean and dirty side of the filters Observe it to check the status of the filters Replace the filters when it indicates 15cm H2O 4 4 Transport Please read chapter 3 7 Transport safety Be careful Make sure nobodies feet ...

Страница 13: ...g the turning direction of the motors Switch off all motors and put the main power switch to the OFF position Wait for a complete standstill of all drives Open the control box of the machine Set the inverter switch to the opposite position Close the control box and check the turning direction of the motor again 5 2 Starting stopping the machine Connect the dust hose between the machine to be used ...

Страница 14: ...ct the power supply cable Prevent unauthorized persons from getting access to the dust collector or take measures to prevent unauthorized working with the equipment 5 5 Emptying the dust bin Operators should observe all safety regulations appropriate to the materials being handled ATTENTION Wear a dust mask of at least class FFP3 The level of the dustbin must be regularly checked The periods are d...

Страница 15: ...ide the water separator Check the tension of the V belts Annually Full overhaul and cleaning of the complete dust collector Oil change of the compressor The time indications are based on uninterrupted operation When the indicated number of working hours is not achieved during the corresponding period the period can be extended However a full overhaul and a technical inspection must be carried out ...

Страница 16: ...es the difference between the under pressure above the filters and inner filter house This readout indicates the degree of pollution of the filters with this system you can always keep an eye on the condition and pollution of the filters inside the dust extractor It can also help you fine tune the airflow when precise adjustment is required for the job If the dust collector loses suction power fir...

Страница 17: ...regulates the systems pressure and then builds up pressure in the pulse tank Normally the pressure in the system lies between 6 and 7 bar The safety valve mounted on the compressor is activated at approximately 10 bar This provision is to ensure that when there is a defect in the Control valve the pressure in the pulse tank remains within safe limits If the pressure of 7 bar is not reached it is p...

Страница 18: ...ater separator If there is condensate level approximately 10 mm below the level indicator marking see figure below then either press in or turn the outlet ring as shown on figure below In case of less air flow as mentioned in the paragraph above replace the filter element of the water separator ...

Страница 19: ...cation C T 68 ISO 68 viscosity Blastrac Compressor oil Part nr E00498 Prior to draining off the oil the compressor unit should have operating temperature Check oil level 2 or 3 minutes after stopping The compressor is factory filled with synthetic oil Because of the rough conditions Blastrac recommends to use synthetic oil Oil must be visible in oil sight glass but never above or below the red poi...

Страница 20: ...erent circumstances Area influences like open outside or closed inside space daily use poor maintenance etc will give different values at all time and could increase the exposure level over the total working period The values may be measurements from a representative sample of technically comparable machinery The values may be used for a preliminary assessment of exposure Always use ear protection...

Страница 21: ...ngton Sheffield South Yorkshire GB S25 3QY England Tel 0044 1909 56 91 18 Fax 0044 1909 56 75 70 Info blastrac co uk Blastrac Germany Richard Byrd Straβe 15 D 50829 Köln Ossendorf Tel 0049 221 70 90 32 0 Fax 0049 221 70 90 32 22 Info blastrac de Blastrac Spain Calle Copernico 16 Nave 2 E 28820 Coslada Tel 0034 91 660 10 65 Fax 0034 91 672 72 11 Info blastrac com es Blastrac France ZI 29 Avenue des...