14
5.4
Interrupting work
When temporarily interrupting the work (1/2 hour – 1 hour), only close the butterfly valve. Pulse
cleaning of the filter system will continue and will increase the life-time of the filter cartridges.
During a longer stand still of the dust collector, close the butterfly valve and let the pulse cleaning
cycle run for +/- 5 minutes. Turn the machine off. Remove water from the air tank.
Close the butterfly valve of the inlet when the machine is turned off. This prevents moisture, dust and
other contaminants to enter the machine.
Disconnect the power-supply cable.
Prevent unauthorized persons from getting access to the dust collector or take measures to prevent
unauthorized working with the equipment.
5.5
Emptying the dust bin
Operators should observe all safety regulations appropriate to the materials being handled.
ATTENTION! Wear a dust mask of at least class FFP3!
The level of the dustbin must be regularly checked. The periods
are dependent on the type of surface preparation being carried
out.
Flip the protectors up and grab the red handles of the toggle
clamps. Carefully move them downwards until they can be
unhooked. Remove and empty the dustbin.
WARNING:
Pay attention to the increased weight
of the dustbin when you loosen the hopper toggle clamps.
Loosen the clamps with caution!