rejection. Therefore, the system must follow this rule.
Coaxial cables’ outer conductor and isolation layer should keep proper electric
conducting with the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be
antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no
less than 25mm
2
.
Signal and Network Management (NMS) Cable Connection
The signal connections include the connection of input signal cable and the connection of
output signal cable. Please use at least CAT 5 STP RJ45 LAN Cable for the management port
and CAT 6 DSTP for the streaming data ports to avoid electromagnetic influences. For RF
cable we recommend double shielded Coax.
Web NMS Management
This device does not support an LCD operation, and the modification can only be operated
with Web NMS by using a standard web-browser. We recommend to use Firefox – latest
version.
Web-Interface access:
Default IP address = 192.168.0.136
User/pw = admin/admin