background image

 

Page - 17 - 

BLANKOM HDC-6008CI  EN 2017 V1.1, RR, 12-2017 

 

HDC 6008CI 

 

So again we go into 

PID-Bypass

 

 

Adding the EIT PID number 0x0012 from source input 2. 

 

Yes, that works 

 

We can do this for the SAT-based Time and date + offset tables TDT/TOT 0x0014: 

Содержание HDC 6008CI

Страница 1: ...llite and IPTV channels decrypted re encrypted and can be combined in a 4 RF DVB C group and distributed over coaxial cable to large networks BLANKOM HDC 6008CI is a high performance and cost effectiv...

Страница 2: ...4 satellites Multiplexing 4 multiplexers Maximum PID remapping 128per input channel PID remapping non automatically or manually PCR re clocking Generation of PSI SI table automatically PID adding man...

Страница 3: ...work Management NMS Cable Connection 6 Web NMS Management 6 Web Interface access 6 Setting NTP Server and Timezone 7 Setting up Tuner Inputs 8 Transportstream TS Config Menu 9 Setting up incoming IP s...

Страница 4: ...output channels where every of these can be scrambled with max 4 simulcrypt Conditional Access Server CAS and all output as 4x MPTS channels it supports a maximum of 128 IP input streams through the...

Страница 5: ...QAM Modulator Connecting signal cables Connecting communication port for WEB IF Be sure to avoid shortage and all cables are installed properly before use the Power On switch Power cord connection Th...

Страница 6: ...g electric circuit The area of the conduction between grounding wire and device s frame should be no less than 25mm2 Signal and Network Management NMS Cable Connection The signal connections include t...

Страница 7: ...NTP Server and Timezone And updated Local Time Date settings are important if an own TDT TOT table should be generated and inserted in the GENERAL TS config sub menu for each output if supported Plea...

Страница 8: ...derstand just Edit every Tuner 1 8 We assume that the user is familiar with LNB Settings SAT Transponder settings and polarisations V H 13V 18V High Low Band High Band 22 KHz ON and DiSEqC Satellite 1...

Страница 9: ...For every TS Output the Input sources can be used and selected We recommend to use PID remapping only if you await collisions from different sources CA Filter usage is only recommended if you have CA...

Страница 10: ...single one to extract read the containing services If you like to keep EIT and other addon tables somehow do not do PID Remapping CA filter is for deleting unnecessary encryption tables and EMM ECM P...

Страница 11: ...t multiple addresses in one shot by using the step counter Than parse the content Remark The IP Input stream is always only valid for your former selected ouput TS number Next TS one You need to impor...

Страница 12: ...MPTS which doesn t contain one and the NIT will be passed by another channel for the receivers in the cable network In MuX mode you can select any pre configured Inpuits stream from Tuner 1 8 and IP I...

Страница 13: ...Page 13 BLANKOM HDC 6008CI EN 2017 V1 1 RR 12 2017 HDC 6008CI...

Страница 14: ...are ready But we like to pass all necessary information from SAT IN to QAM out To just remark these both Tables has PID No EIT PID 0x0012hex TDT TOT PID 0x0014hex and can be added to the mux from its...

Страница 15: ...Page 15 BLANKOM HDC 6008CI EN 2017 V1 1 RR 12 2017 HDC 6008CI As to bee seen EIT and TDT TOT are there We delete both And they are still there from the original source...

Страница 16: ...R 12 2017 HDC 6008CI Because we accidently used the passthrough mode and therefore the manual PID adding has no effect We better change to mux mode Check IP output stream A lot of things are missing b...

Страница 17: ...C 6008CI EN 2017 V1 1 RR 12 2017 HDC 6008CI So again we go into PID Bypass Adding the EIT PID number 0x0012 from source input 2 Yes that works We can do this for the SAT based Time and date offset tab...

Страница 18: ...most tables are somehow cross referencing If you change a SID or remap a PID the EIT is not valid any more AIT as well BAT might also not fully work in the output network Also adding a TV Service fro...

Страница 19: ...V1 1 RR 12 2017 HDC 6008CI The arrow of OVERFLOW in the right side changes to RED if an overflow is happening So we try an SD channel to inject here Remove than delete the input SPTS and use another A...

Страница 20: ...Page 20 BLANKOM HDC 6008CI EN 2017 V1 1 RR 12 2017 HDC 6008CI We might have still some space and insert another considering the bitrate Some radios will fit Even from different input sources...

Страница 21: ...General An IPTV Input as MPTS can be passed to the output as well CI Card using Decryption by CAM After all TS Inputs are configured the CI Modules inserted can be used for every of the Input streams...

Страница 22: ...Page 22 BLANKOM HDC 6008CI EN 2017 V1 1 RR 12 2017 HDC 6008CI...

Страница 23: ...Page 23 BLANKOM HDC 6008CI EN 2017 V1 1 RR 12 2017 HDC 6008CI Select the Services to be decrypted and Set programm SET it and...

Страница 24: ...ervices and datrates will be shown which are routed now through the CAM Modulator settings The QAM channels are connected to the 4x IP MPTS output streams They will contain exactly the same Transports...

Страница 25: ...r all Single settings can be accessed individually but becasue we have a common modulator for all and adjacent the single setting will affect the others where we set start center frequency other will...

Страница 26: ...dec 0x1FFF hex can be filtered out You would sent a VBR instead of a CBR stream This safes bandwidth but can cause problems in stupid IP 2 QAM devices in sub headends UDP or RTP can be chosen Scramble...

Страница 27: ...ent scrambling encryption channels can be designed with up to 4 times simulcrypt Single PID s can be chosen individually to encrypt them Which need to be setup in conjunction with the setup of the Net...

Страница 28: ...system has been approved by CQC organization We guarantee the products quality reliability and stability All of our products have been passed the testing and inspection before shipping out from facto...

Страница 29: ...this device or system requires special electronic technical knowledge To reduce the risk of electrical shock or damage to the equipment do not perform any servicing other than the installation and op...

Страница 30: ...s the second power connector is feeding another independent power supply for internal redundancy For a maximum of redundancy both power supplies should use different circuits All the outputs are decou...

Страница 31: ...l abbreviations mentioned in this manual Contact IRENIS GmbH Owiesenkehre 1 D 22177 Hamburg Germany Managing Director Dipl Ing Riccardo Rossini Commercial Register HRB 130657 District Court Hamburg We...