6
PALIOS-IPM2
Part N
o
: 5105.01
8 pole IP-/ ASI-TV Modulator
IP/ SFP/ ASI (MPEG2)
→
ATV (8x AM)
SBL
7. Adjusting by web server
7.1 Network connection to the computer
System requirements:
- PC/ laptop with 10/ 100 Mbit Ethernet interface
- Internet browser (e.g. Windows Internet Explorer), which accept JAVA script.
Setup the connection:
The PALIOS-IPM2 module has to be connected to PC network using an Ethernet cable.The IP address of the PALIOS-IPM2 module is
192.168.1.100 on delivery. If several SBL modules should be controlled or adjusted via an Ethernet switch, each module must
first be configured
individually
to its provided IP address within the network. To do so the address of the network port on the PC
(temporary) must be adapted to the IP address of the SBL module (subnet mask: 255.255.255.0, IP address: 192.168.1.XXX,
where XXX is not the same as the corresponding value of the SBL module IP address).
After the network configuration of the module(s) the IP address of the control PC is converted to the provided IP address and the
modules can be accessed through the browser with their new IP addresses. The user must authenticate himself with his credentials
(user name and password), if the password and user testing were activated on the setup page (see chapter 7.2.6):
After successful registration or successful connection establishment without password (default setting) the start page of the module is
the menu “Overview“ (see chapter 7.2.1).