1. Safety and operating instructions

 

When assembling, starting-up and adjusting the modules, it is necessary to consider the system specific references in

 

the instruction manual.

 

The modules may only be installed and started up by authorized technical personnel. There are only permitted the  

 

mounting styles indicated in the quick start guide, included with each module.

 

When assembling the modules into the receiving points, the adherence of the EMC regulations is to be ensured.

 

The assembly and wiring have to be done without voltage. For installation, only the supplied accessories (DIN rail clip    
with screws and 19“ accessories) may only be used.

 

All active modules may only be powerd by the power supply HELIOS, HELIOS-P1 or QUASARIOS. Only connect the modu-
le with the accessory cables provided.

 

The mains voltage and the operating voltage of the modules working by DC have to be in compliance with the operating

 

parameters described in the technical data. 

 

With all work the defaults of the DIN EN 50083 have to be considered. It is especially important to follow 

 

DIN EN 60728-11[2].

 

The unit must only be mounted vertically. The ventilation slots as well as the circulation perforation of the modules is not be  

 

obstructed in any way.

 

If installed in mounting cabinets a adequate heat circulation must be guaranteed. The mounting in closed cabinets without   

 

air sufficient flow is 

not allowed

.

 

For 

DIN rail mounting

 is important to note that between the heat sink and a neighboring module, a distance of 2 cm is

required. If the modules mounted on top of each, so they must be spaced 20 cm apart.

 

For 

19“ mounting

 all devices in the rack must be fitted with 19“ Edge Guide. Mounting the device using only the screw

 

holes at the front panel is insecure and discouraged. Furthermore, the operation of a fully occupied rack is only allowed  

 

with an underlying 1-U fan box (at least 3 fans, 176 mm deep).

2. Device variants

PALIOS-IPM2   

5105.01  IP/ SFP/ ASI (MPEG2) 

→ 

ATV (8x AM)

3. General

The Smart Business Line (SBL) is a modern head end system, that is distinguished by its modular and compact design. A
userfriendly operating concept facilitates setup, configuration and maintenance of the system.
The PALIOS-IPM2 module selects 8 programs from up to 8 adjacent IP transport streams or from an ASI transport stream and 
converts these into analoge TV signals to transmit it in cable networks. In this case, a maximum of 8 analog television channels 
are generated from the available MPEG2 transport streams.

WEEE-Reg.-Nr. DE 50389067

Содержание 5105.01

Страница 1: ...Professional Headend Solutions Operating instructions PALIOS IPM2 Part No 5105 01 8 pole IP ASI TV Modulator IP SFP ASI MPEG2 ATV 8x AM...

Страница 2: ...Status LED s 5 6 5 LED s at the 10 100 Mbit control port 5 7 Adjusting by web server 6 7 1 Network connection to the computer 6 7 2 Setting of individual parameters 7 7 2 1 Menu Overview 8 7 2 2 Menu...

Страница 3: ...ted vertically The ventilation slots as well as the circulation perforation of the modules is not be obstructed in any way If installed in mounting cabinets a adequate heat circulation must be guarant...

Страница 4: ...tion and sum level adjustment the cable signal is coupled through a directio nal coupler to the output jacks 6 Meaning of the LED s 6 1 LED s at the 10 100 1000 Mbit stream port 1 Designation colour S...

Страница 5: ...f display POWER green permanently on module is on amber permanently on module is in standby off module is off operating voltage is not applied SYSTEM green permanently on module is ready for work flas...

Страница 6: ...P address within the network To do so the address of the network port on the PC temporary must be adapted to the IP address of the SBL module subnet mask 255 255 255 0 IP address 192 168 1 XXX where X...

Страница 7: ...may be selected so that the help appears in the status bar of your browser If appro priate setting changes in the browser options are necessary In addition in the lower part of the navigation tree sta...

Страница 8: ...sh top right 7 2 1 Menu Overview This page provides a status overview of the 8 channels If a channel is working without errors SYNC is displayed If errors occur you will see an Error display If the RF...

Страница 9: ...is available only after enabling the associate software option see section 7 2 6 The IP address subnet mask and gateway can be configured for each port The next step is to configure the setup paramete...

Страница 10: ...how to switch Inclusion in the monitoring is configured on a per channel basis This is a global option deciding when to switch either when an input channel is down or all monitored channels have fail...

Страница 11: ...xt both columns there can be selected the language respective the language of the subtitles if there are more than one of them In the column Output frequency there is to be selected the output channel...

Страница 12: ...ID of the selected program Type displays the type of the program Language selection of the available language Direct input selection selection menu direct input see be low Selected program variant 2...

Страница 13: ...TSC Video format selection letterbox center cut 1 1 pillarbox 4 3 vertical cut 20 9 letterbox Audio setting of the audio parameters Audio gain adjustment range 6 20 dB Audio mode selection 1 mono L mo...

Страница 14: ...standard table alternative table no country code English German Swedish Italian French Spanish Czech Rumanian Polish Esto nian Latvian Serbian Turkish Danish only available if Subtitling option is en...

Страница 15: ...selection of the user interface language is executed You can choose between German and English The transition can be made either to the left in the navigation tree in the subtree of the point language...

Страница 16: ...rowser pages is greatly reduced So it is possible to adjust the module if there is only a low speed connectivity GSM The available reduction is achieved by reducing image size Output frequency raster...

Страница 17: ...ad of the current PA LIOS IPM2 releases the current QAMOS IP release is to select and then perform the update process If the option is not enabled after selecting the QAMOS IP releases appears op posi...

Страница 18: ...nfigure the DHCP range from which the IP addresses of the connected clients are assigned The address range must match the address range according to IP address and subnet mask of the server and should...

Страница 19: ...configured whether and partly with what thresholds they should trigger traps There are three ways to configure a trap without parameters e g fan on off with a freely selectable parameter for a medium...

Страница 20: ...e release is displayed 7 2 8 Menu Level With the top box the loop through output loop is enabled or disabled If enabled the underlying selection of the nominal level for all 8 channels may be set in t...

Страница 21: ...It lists only the current va lues the naming of the parameter appears in the help box in the lower part of the user interface or in the status bar of the browser as adopted configuration if you hover...

Страница 22: ...eboot i e the module restarts and all stored values are adjusted If the module is to be reset to factory settings the reset button must be pressed so long to keep up until the POWER and SYSTEM LED wil...

Страница 23: ...SFP CONTROL STREAM IP TS ASI TS 8xPAL PALIOS IPM2 ASI RJ45 SFP CONTROL STREAM IP5 IP3 IP4 IP2 IP1 SWITCH ETHERNET PALIOS IPM2 HELIOS PALIOS IPM2 LANIOSs PALIOS IPM2 ASI signal input IP signal input 1...

Страница 24: ...processing EN 50083 9 1 MPEG decoder Video MPEG 2 MP ML Audio Audio description MPEG 1 Layer 1 2 TV output TV standard B G D K Sound type double carrier FM Sound carrier frequencies B G 5 5 5 742 MHz...

Страница 25: ...eams 2 EN 60728 11 Cable networks for television signals sound signals and interactive services Part 11 Safety IEC 60728 11 2005 German version EN 60728 11 2005 3 EN 50083 2 Cabled distribution system...

Страница 26: ...the conformity of the product Product name IP ASI TV Transmodulator Type PALIOS IPM2 Product number 5105 01 according to the following regulations EN 50083 2 3 EN 60728 11 2 as far as relevant and add...

Отзывы: