English
TABLE OF ALARM INDICATIONS
Alarm
Cause
Remedy
ALL
Safety thermostat with automatic
reset tripped.
Allow the appliance to cool and
return it to ON status.
Important
If the problem persists, con-
tact the After Sales Service.
Err
Thermocouple TCJ has failed or is
not properly connected.
Important
Contact the after-sales ser-
vice.
Check the condition of
thermocouple TCJ and the
electrical connections.
Improper use of the appliance,
such as sudden changes in
temperature (thermal shock).
The appliance switches to stand-
by status.
Allow the appliance to cool
and return it to ON status.
Er3
Electronic circuit board
diagnostics tripped.
Replace the electronic
circuit board
Important
Contact the after-sales
service.
Er4
Electronic circuit board heat
sensor tripped.
The appliance switches to
stand-by status.
Allow the appliance to
cool and return it to ON status.
Important
If the problem persists, con-
tact the After Sales Service.
Fan malfunction.
The appliance switches to
stand-by status.
Important
Contact the after-sales ser-
vice.
Check the condition of the fan and
the electrical connections.
Air intake line blocked.
The appliance switches to
stand-by status.
Clean the air intake lines
Important
If the problem persists, con-
tact the After Sales Service.