USA
page 25
INSTALLER SECTION
code 10799
C
D
B
A
10807
10806
10805
10805
10805
PROBLEMS
CAUSES AND SOLUTIONS
Water exits from the rinse aid suction tube
The suction valves 10805 and delivery do not seal due to foreign bodies
in the closing seats. Clean the valves 10805, check that the rinse aid
suction filter is present, and filter the water entering the dishwashwer
The dispenser does not draw rinse aid
a) The delivery valve 10805 does not seal due to foreign bodies in the
closing seats. Clean the valve 10805, check that the rinse aid suction
filter is present and filter the water entering the dishwasher
b) The piston seal 10806 does not hold because it is damaged.
Replace the seal 10806 with an original
c) Check the diaphragm 10807
Содержание D-18