If either the pump or the SPILLSTOP do not operate normally after installation, maintenance or service, follow the steps below in the 

order shown to source and fix the problem.

1.  The SPILLSTOP requires a constant and separate source of compressed air to function properly. With the pump in operation and 

air supplied to the SPILLSTOP, adjust the Regulator and verify the gauge reads 40 psi (2.7 bar) or higher.

2.  Disconnect all air supply to the pump and SPILLSTOP. Connect an air line to the Regulator and disconnect the plastic tube at  

Port 2 of the Actuator Valve. Adjust the Regulator to a minimum of 40 psi (2.7 bar). Air should be flowing from Port 2.

a. 

If air is not flowing from Port 2, the Actuator Valve may be clogged or damaged and should be cleaned or replaced.

b. 

If air is flowing from Port 2, check the tubing to the Pump Shutoff Valve to ensure air can flow from the Actuator Valve to the 

Shutoff Valve during normal operation.

3.  Disconnect the air line to the Regulator. Uninstall the SPILLSTOP completely from the pump and system, and restart the pump.

a.  If the pump does not operate normally after removing the SPILLSTOP, refer to the pump manual or contact the pump 

manufacturer for instructions to repair the pump.

4. 

Disconnect all air supply to the pump and reinstall the exhaust hose from the pump’s air discharge port (exhaust) to the 

SPILLSTOP Inlet connection port. Do not connect SPILLSTOP Shutoff Valve(s). 

a.  Check that pump exhaust is entering the SPILLSTOP through the Inlet connection port and exiting through the Test Port Plug.
b.  Start the pump to ensure the pump operates normally.

5. 

Disconnect all air supply to the pump and SPILLSTOP. Remove the SPILLSTOP lid and flush internal areas with water or cleaner 

appropriate for the process fluid being pumped.

a.  Connect an air line to the Regulator and disconnect the plastic tube at Port 2 of the Actuator Valve. Adjust the Regulator to a 

minimum of 40 psi (2.7 bar). Air should be flowing from Port 2. 

b.  Activate the SPILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down. Air should stop 

flowing from Port 2.

c. 

If air does not stop flowing from Port 2 when the SPILLSTOP is activated, the Actuator Valve may be clogged or damaged and 

should be cleaned or replaced.

6.  Reassemble the SPILLSTOP and reconnect Shutoff Valve(s). Adjust the Regulator to a minimum of 40 psi (2.7 bar) to restart the 

pump.

a.  If the SPILLSTOP is installed with a Whistle and/or more than two Shutoff Valves, increase pressure to a minimum of 60 psi (4.1 

bar).

7.  Ensure SPILLSTOP Shutoff Valve(s) open when the system is operating.

a.  To visually inspect a valve, it is possible to see the piston lift approximately 0.25” from its seat when viewed through Port B.
b. 

To mechanically inspect a valve, connect a fitting to Port A and supply compressed air to that fitting. If air escapes Port B, the 

valve is open.

8.  Disconnect all air supply to the pump and SPILLSTOP and reinstall the Pump Shutoff Valve. Verify that compressed air is supplied 

to Port A and that the pump’s air inlet is connected to Port B. Reapply compressed air to the SPILLSTOP to start the pump. If the 

pump does not operate normally, the valve may be undersized for the application. Contact Blacoh for assistance.

9.  If using an Exhaust Shutoff Valve, disconnect all air supply to the pump and SPILLSTOP and reinstall the valve. Verify that the 

pump’s exhaust is connected to Port A and the SPILLSTOP is connected to Port B. Reapply compressed air to the SPILLSTOP 

to start the pump. If the pump is not operating normally, the valve may be undersized for the application. Contact Blacoh for 

assistance.

Troubleshooting

3.  Test the Pressure Switch before putting the SPILLSTOP into operation.

a.  Connect an air line to the Regulator and adjust the Regulator to a minimum of 40 psi (2.7 bar). If the SPILLSTOP is installed 

with a Whistle and/or more than two Shutoff Valves, increase pressure to a minimum of 60 psi (4.1 bar).

b.  Activate the SPILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down. Air should start 

flowing through the tube connected to Port 3 of the Actuator Valve and the Pressure Switch should power on the electrical 

device.

Содержание SPILLSTOP

Страница 1: ...ment at risk The fully pneumatic SPILLSTOP system prevents the hazardous spill by safely capturing expelled fluid and automatically shutting down the failed pump Optional warning alarm and backup pump switchover further minimize system downtime for maximum productivity Visit www Blacoh com for literature online Installation and Operation Manual ...

Страница 2: ...ifications Installation Information Model No Serial No Installation Date Body Material Lid Float Material Pump Area and Number Purchased From Contact Phone Email Table of Contents Safety Warnings 2 General Safety 2 ATEX Standard 2 Installation Operation Instructions 3 Shutoff Valves 3 Installation 3 Operation 3 Service 4 Maintenance 4 Optional Whistle 4 Optional Pressure Switch 4 Troubleshooting 5...

Страница 3: ...ILLSTOP with incompatible fluids Consult distributor or factory if you are not sure of the compatibility of fluids with SPILLSTOP Static spark can cause an explosion resulting in severe injury or death Ground SPILLSTOP and pumping system when pumping flammable fluids or operating in flammable environments WARNINGS Danger of serious injury or death could occur if these warnings are ignored CAUTIONS...

Страница 4: ...for the connection from the pipe to the Inlet connection port 3 If using an Exhaust Shutoff Valve when there is positive inlet pressure to the pump install the Exhaust Shutoff Valve in the pump exhaust line at the SPILLSTOP Inlet connection port Figures B and D This valve will close whenever the pump is shut down regardless of whether the SPILLSTOP is activated or not 4 Connect 1 4 plastic tubing ...

Страница 5: ...ng the SPILLSTOP into operation a Connect an air line to the Regulator and adjust the Regulator to a minimum of 40 psi 2 7 bar If the SPILLSTOP is installed with more than two Shutoff Valves increase pressure to a minimum of 60 psi 4 1 bar b Activate the SPILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down Air should start flowing through the tube connected to ...

Страница 6: ...PILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down Air should stop flowing from Port 2 c If air does not stop flowing from Port 2 when the SPILLSTOP is activated the Actuator Valve may be clogged or damaged and should be cleaned or replaced 6 Reassemble the SPILLSTOP and reconnect Shutoff Valve s Adjust the Regulator to a minimum of 40 psi 2 7 bar to restart t...

Страница 7: ...e to pump it is recommended to install an additional Shutoff Valve Compressed Air to Pump Air to open valve normally closed N C Pump Exhaust Air to SPILLSTOP Connect to Pump Exhaust To optional Whistle Switch WHISTLE Option PRESSURE SWITCH Option N C COM N O TUBING CONNECTION PUMP SHUTOFF VALVE PRIMARY PUMP Port 2 normally open no fluid in SPILLSTOP DRAIN VALVE Port 3 normally closed open when flu...

Страница 8: ...ion OUTLET SPILLSTOP FROM SHOP AIR TUBING INLET ACTUATOR VALVE PUMP EXHAUST AIR PRIMARY PUMP DRAIN SILENCER RECLASSIFIER WHISTLE Option Figure A SPILLSTOP Installation Diagram 1 Pump Shutoff Valve PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP Figure A 1 Pump Shutoff Valve ...

Страница 9: ...CTUATOR VALVE PUMP EXHAUST AIR PRIMARY PUMP DRAIN SILENCER RECLASSIFIER WHISTLE Option Figure B SPILLSTOP Installation Diagram 1 Pump Shutoff Valve 1 Exhaust Shutoff Valve PUMP SHUTOFF VALVE ELEVATED TANK EXHAUST SHUTOFF VALVE COMPRESSED AIR TO PUMP PROCESS FLUID Figure B 1 Pump Shutoff Valve 1 Exhaust Shutoff Valve ...

Страница 10: ...PILLSTOP Installation Diagram 3 Pump Shutoff Valves PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP PUMP SHUTOFF VALVE PUMP SHUTOFF VALVE BACKUP PUMP ADDITIONAL PUMP TUBING PUMP EXHAUST AIR HOSE TUBING TUBING Single SPILLSTOP protects multiple pumps with 1 shutoff valve per pump On larger pumps multiple valves could cause reduction in flow due to restriction added to pump exhaust Figure C 3 Pump Shutoff...

Страница 11: ...ves 1 Exhaust Shutoff Valve PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP PUMP SHUTOFF VALVE PUMP SHUTOFF VALVE BACKUP PUMP ADDITIONAL PUMP TUBING PUMP EXHAUST AIR HOSE TUBING EXHAUST SHUTOFF VALVE ELEVATED TANK PROCESS FLUID TUBING Single SPILLSTOP protects multiple pumps with 1 shutoff valve per pump On larger pumps multiple valves could cause reduction in flow due to restriction added to pump exhau...

Страница 12: ...urn Policy Details regarding warranty and return policy are available on Blacoh s website at www Blacoh com PROUDLY MANUFACTURED IN THE USA Blacoh Headquarters 601 Columbia Ave Bldg D Riverside CA 92507 USA 951 342 3100 www Blacoh com Sales Blacoh com ...

Отзывы: