When there is a leak through the pump diaphragm, process fluid enters the pump’s air exhaust and is carried to the SPILLSTOP. 

 

As process fluid is accumulated in the SPILLSTOP, the internal Float is raised and airflow is shifted through the Actuator Valve from 

Port 2, the air line connected to the Pump Shutoff Valve, to Port 3 (Figure 1). When this shift occurs, air pressure is removed from the 

Pump Shutoff Valve which in turn closes the valve to shut down the pump and prevent the spill. At the same time, the air pressure 

shifted to Port 3 of the Actuator Valve is used to pneumatically power the optional Whistle, Power Switch, and/or an additional Pump 

Shutoff Valve to automatically start a standby pump.
When the SPILLSTOP triggers a pump shutdown, the most likely cause is a failed pump diaphragm. Excessive moisture laden 

compressed air can also cause the SPILLSTOP to trigger a shutdown, simulating a failed pump diaphragm. 
Follow the steps below when a pump shutdown occurs:

1.  Turn off all air supply to the pump and SPILLSTOP.
2. 

Drain the contents of the SPILLSTOP into a container appropriate for the process fluid being pumped by opening the Drain Valve 

on the bottom of the SPILLSTOP. A tube or hose should be attached to the Drain Valve when draining fluid.

3. 

If fluid drained from the SPILLSTOP is water condensation only, no further action is necessary. Close the Drain Valve and turn on 

the air supply to the pump and SPILLSTOP to restart the pump. 

4. 

If the process fluid being pumped is found in the SPILLSTOP, the pump must be repaired immediately to minimize internal damage 

and the SPILLSTOP must be serviced.

Operation

1.  Install the Pump Shutoff Valve directly to the air inlet of the pump (Figure A). This valve can be installed before or after any 

regulator or lubricator installed in the compressed air line. Refer to Figures B-D for appropriate valve locations and air line 

connections when installing multiple valves. 

The Pump Shutoff Valve must be installed so that air flows into the valve through Port A (or Port 1 depending on 

valve design), and exits the valve through Port B (or Port 2) towards the pump�

2. 

Install an exhaust hose with a pressure rating at least as high as the system air pressure, from the pump’s air discharge port 

(exhaust) to the SPILLSTOP Inlet connection port. Alternatively, rigid piping may be used; however, a minimum 6” (15.2 cm) length 

of hose should be used for the connection from the pipe to the Inlet connection port.

3.  If using an Exhaust Shutoff Valve when there is positive inlet pressure to the pump, install the Exhaust Shutoff Valve in the pump 

exhaust line at the SPILLSTOP Inlet connection port (Figures B and D). This valve will close whenever the pump is shut down, 

regardless of whether the SPILLSTOP is activated or not. 

4.  Connect 1/4” plastic tubing from the Pump Shutoff Valve to Port 2 of the SPILLSTOP Actuator Valve (Figure 1).

Since the Pump Shutoff Valve is a normally closed valve, the pump will not operate unless compressed air is supplied 

to the Pump Shutoff Valve. Air supplied to the Pump Shutoff Valve must flow through the SPILLSTOP Actuator Valve in 

order for the SPILLSTOP to shut down the pump when a leak is detected�

5.  Connect an air line with a 1/4” (6.4 mm) female quick connect to the 1/4” (6.4 mm) male quick connect on the SPILLSTOP 

Regulator. The quick connect can be removed for hard plumbing.

6.  Adjust the Regulator to a minimum of 40 psi (2.7 bar) to start the pump. If the SPILLSTOP is installed with a Whistle and/or more 

than two Shutoff Valves, increase pressure to a minimum of 60 psi (4.1 bar).

7. 

Mounting the SPILLSTOP Stand to the floor or table is not required; however, the Stand includes footpads with holes for this 

purpose. 

8.  The SPILLSTOP is now operational. When compressed air is supplied to the pump, the SPILLSTOP will operate normally. Exhaust 

air from the pump will flow into the SPILLSTOP and out of the SPILLSTOP Silencer/Reclassifier.

Installation

Depending on the model, SPILLSTOP includes one to four Shutoff Valves. Additional Shutoff Valves are available from Blacoh.

Pump Shutdown:

 Installed at the pump inlet, the Pump Shutoff Valve automatically shuts down the pump in the event of a diaphragm 

failure. A single SPILLSTOP can protect multiple smaller air operated diaphragm pumps (1/2” or 1” models) by routing all of the pump 

exhausts through the SPILLSTOP and installing additional Pump Shutoff Valves for each pump. It is possible to do this with larger 

pumps but, there could be a significant reduction in flow due to the restriction added to the pump exhaust.

High Inlet Pressure/Positive Flooded Suction:

 For applications with positive flooded suction (positive inlet pressure to the pump), it 

is recommended to install an additional Shutoff Valve on the pump exhaust line to stop fluid in the tank from flowing through the failed 

diaphragm and out of the pump exhaust when the pump is shut down. For purposes of these instructions, this valve is referred to as an 

Exhaust Shutoff Valve.

Shutoff Valves

Installation & Operation Instructions

Содержание SPILLSTOP

Страница 1: ...ment at risk The fully pneumatic SPILLSTOP system prevents the hazardous spill by safely capturing expelled fluid and automatically shutting down the failed pump Optional warning alarm and backup pump switchover further minimize system downtime for maximum productivity Visit www Blacoh com for literature online Installation and Operation Manual ...

Страница 2: ...ifications Installation Information Model No Serial No Installation Date Body Material Lid Float Material Pump Area and Number Purchased From Contact Phone Email Table of Contents Safety Warnings 2 General Safety 2 ATEX Standard 2 Installation Operation Instructions 3 Shutoff Valves 3 Installation 3 Operation 3 Service 4 Maintenance 4 Optional Whistle 4 Optional Pressure Switch 4 Troubleshooting 5...

Страница 3: ...ILLSTOP with incompatible fluids Consult distributor or factory if you are not sure of the compatibility of fluids with SPILLSTOP Static spark can cause an explosion resulting in severe injury or death Ground SPILLSTOP and pumping system when pumping flammable fluids or operating in flammable environments WARNINGS Danger of serious injury or death could occur if these warnings are ignored CAUTIONS...

Страница 4: ...for the connection from the pipe to the Inlet connection port 3 If using an Exhaust Shutoff Valve when there is positive inlet pressure to the pump install the Exhaust Shutoff Valve in the pump exhaust line at the SPILLSTOP Inlet connection port Figures B and D This valve will close whenever the pump is shut down regardless of whether the SPILLSTOP is activated or not 4 Connect 1 4 plastic tubing ...

Страница 5: ...ng the SPILLSTOP into operation a Connect an air line to the Regulator and adjust the Regulator to a minimum of 40 psi 2 7 bar If the SPILLSTOP is installed with more than two Shutoff Valves increase pressure to a minimum of 60 psi 4 1 bar b Activate the SPILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down Air should start flowing through the tube connected to ...

Страница 6: ...PILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down Air should stop flowing from Port 2 c If air does not stop flowing from Port 2 when the SPILLSTOP is activated the Actuator Valve may be clogged or damaged and should be cleaned or replaced 6 Reassemble the SPILLSTOP and reconnect Shutoff Valve s Adjust the Regulator to a minimum of 40 psi 2 7 bar to restart t...

Страница 7: ...e to pump it is recommended to install an additional Shutoff Valve Compressed Air to Pump Air to open valve normally closed N C Pump Exhaust Air to SPILLSTOP Connect to Pump Exhaust To optional Whistle Switch WHISTLE Option PRESSURE SWITCH Option N C COM N O TUBING CONNECTION PUMP SHUTOFF VALVE PRIMARY PUMP Port 2 normally open no fluid in SPILLSTOP DRAIN VALVE Port 3 normally closed open when flu...

Страница 8: ...ion OUTLET SPILLSTOP FROM SHOP AIR TUBING INLET ACTUATOR VALVE PUMP EXHAUST AIR PRIMARY PUMP DRAIN SILENCER RECLASSIFIER WHISTLE Option Figure A SPILLSTOP Installation Diagram 1 Pump Shutoff Valve PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP Figure A 1 Pump Shutoff Valve ...

Страница 9: ...CTUATOR VALVE PUMP EXHAUST AIR PRIMARY PUMP DRAIN SILENCER RECLASSIFIER WHISTLE Option Figure B SPILLSTOP Installation Diagram 1 Pump Shutoff Valve 1 Exhaust Shutoff Valve PUMP SHUTOFF VALVE ELEVATED TANK EXHAUST SHUTOFF VALVE COMPRESSED AIR TO PUMP PROCESS FLUID Figure B 1 Pump Shutoff Valve 1 Exhaust Shutoff Valve ...

Страница 10: ...PILLSTOP Installation Diagram 3 Pump Shutoff Valves PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP PUMP SHUTOFF VALVE PUMP SHUTOFF VALVE BACKUP PUMP ADDITIONAL PUMP TUBING PUMP EXHAUST AIR HOSE TUBING TUBING Single SPILLSTOP protects multiple pumps with 1 shutoff valve per pump On larger pumps multiple valves could cause reduction in flow due to restriction added to pump exhaust Figure C 3 Pump Shutoff...

Страница 11: ...ves 1 Exhaust Shutoff Valve PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP PUMP SHUTOFF VALVE PUMP SHUTOFF VALVE BACKUP PUMP ADDITIONAL PUMP TUBING PUMP EXHAUST AIR HOSE TUBING EXHAUST SHUTOFF VALVE ELEVATED TANK PROCESS FLUID TUBING Single SPILLSTOP protects multiple pumps with 1 shutoff valve per pump On larger pumps multiple valves could cause reduction in flow due to restriction added to pump exhau...

Страница 12: ...urn Policy Details regarding warranty and return policy are available on Blacoh s website at www Blacoh com PROUDLY MANUFACTURED IN THE USA Blacoh Headquarters 601 Columbia Ave Bldg D Riverside CA 92507 USA 951 342 3100 www Blacoh com Sales Blacoh com ...

Отзывы: