Blacoh SPILLSTOP Скачать руководство пользователя страница 3

TM

 

BLACOH Fluid Control 

2

Certain models made for the European market are intended for use in potentially explosive atmospheres and meet the 

requirements of ATEX directive 2014/34/EU. These models have the AT designation at the end of the part number, comply with 

ISO 80079-36, and have an ATEX rating of II 2GD Ex h IIB T4 Gb Db. AT models have a grounding lug and must be grounded 

(earthed) before operation.

ATEX Standard

General Safety

ATEX models must be grounded (earthed) before operation�

Always wear safety glasses and other appropriate safety equipment when installing or repairing SPILLSTOP.

Temperature limit is determined by the liquid inside the SPILLSTOP and materials of construction. SPILLSTOP has no moving 

parts to generate heat. 

DO NOT use SPILLSTOP with incompatible fluids. Consult distributor or factory if you are not sure of the compatibility of fluids 

with SPILLSTOP.

Static spark can cause an explosion resulting in severe injury or death� Ground SPILLSTOP and pumping system 

when pumping flammable fluids or operating in flammable environments.

WARNINGS

Danger of serious injury or death could occur if these warnings are ignored.

CAUTIONS

Equipment damage, injury or death could occur if these cautions are not observed.

NOTES

Special instructions for safe and satisfactory installation, operation and maintenance.

The following symbols indicate cautions, warnings and notes that must be observed for safe and satisfactory installation, operation and 

maintenance.

Safety Warnings

SPILLSTOP should only be installed, operated and repaired by experienced and trained professional mechanics. Read and observe all 

instructions and safety warnings in this Manual before installing, operating or repairing.

Содержание SPILLSTOP

Страница 1: ...ment at risk The fully pneumatic SPILLSTOP system prevents the hazardous spill by safely capturing expelled fluid and automatically shutting down the failed pump Optional warning alarm and backup pump switchover further minimize system downtime for maximum productivity Visit www Blacoh com for literature online Installation and Operation Manual ...

Страница 2: ...ifications Installation Information Model No Serial No Installation Date Body Material Lid Float Material Pump Area and Number Purchased From Contact Phone Email Table of Contents Safety Warnings 2 General Safety 2 ATEX Standard 2 Installation Operation Instructions 3 Shutoff Valves 3 Installation 3 Operation 3 Service 4 Maintenance 4 Optional Whistle 4 Optional Pressure Switch 4 Troubleshooting 5...

Страница 3: ...ILLSTOP with incompatible fluids Consult distributor or factory if you are not sure of the compatibility of fluids with SPILLSTOP Static spark can cause an explosion resulting in severe injury or death Ground SPILLSTOP and pumping system when pumping flammable fluids or operating in flammable environments WARNINGS Danger of serious injury or death could occur if these warnings are ignored CAUTIONS...

Страница 4: ...for the connection from the pipe to the Inlet connection port 3 If using an Exhaust Shutoff Valve when there is positive inlet pressure to the pump install the Exhaust Shutoff Valve in the pump exhaust line at the SPILLSTOP Inlet connection port Figures B and D This valve will close whenever the pump is shut down regardless of whether the SPILLSTOP is activated or not 4 Connect 1 4 plastic tubing ...

Страница 5: ...ng the SPILLSTOP into operation a Connect an air line to the Regulator and adjust the Regulator to a minimum of 40 psi 2 7 bar If the SPILLSTOP is installed with more than two Shutoff Valves increase pressure to a minimum of 60 psi 4 1 bar b Activate the SPILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down Air should start flowing through the tube connected to ...

Страница 6: ...PILLSTOP by pushing the Float up or raise the Float by turning the SPILLSTOP upside down Air should stop flowing from Port 2 c If air does not stop flowing from Port 2 when the SPILLSTOP is activated the Actuator Valve may be clogged or damaged and should be cleaned or replaced 6 Reassemble the SPILLSTOP and reconnect Shutoff Valve s Adjust the Regulator to a minimum of 40 psi 2 7 bar to restart t...

Страница 7: ...e to pump it is recommended to install an additional Shutoff Valve Compressed Air to Pump Air to open valve normally closed N C Pump Exhaust Air to SPILLSTOP Connect to Pump Exhaust To optional Whistle Switch WHISTLE Option PRESSURE SWITCH Option N C COM N O TUBING CONNECTION PUMP SHUTOFF VALVE PRIMARY PUMP Port 2 normally open no fluid in SPILLSTOP DRAIN VALVE Port 3 normally closed open when flu...

Страница 8: ...ion OUTLET SPILLSTOP FROM SHOP AIR TUBING INLET ACTUATOR VALVE PUMP EXHAUST AIR PRIMARY PUMP DRAIN SILENCER RECLASSIFIER WHISTLE Option Figure A SPILLSTOP Installation Diagram 1 Pump Shutoff Valve PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP Figure A 1 Pump Shutoff Valve ...

Страница 9: ...CTUATOR VALVE PUMP EXHAUST AIR PRIMARY PUMP DRAIN SILENCER RECLASSIFIER WHISTLE Option Figure B SPILLSTOP Installation Diagram 1 Pump Shutoff Valve 1 Exhaust Shutoff Valve PUMP SHUTOFF VALVE ELEVATED TANK EXHAUST SHUTOFF VALVE COMPRESSED AIR TO PUMP PROCESS FLUID Figure B 1 Pump Shutoff Valve 1 Exhaust Shutoff Valve ...

Страница 10: ...PILLSTOP Installation Diagram 3 Pump Shutoff Valves PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP PUMP SHUTOFF VALVE PUMP SHUTOFF VALVE BACKUP PUMP ADDITIONAL PUMP TUBING PUMP EXHAUST AIR HOSE TUBING TUBING Single SPILLSTOP protects multiple pumps with 1 shutoff valve per pump On larger pumps multiple valves could cause reduction in flow due to restriction added to pump exhaust Figure C 3 Pump Shutoff...

Страница 11: ...ves 1 Exhaust Shutoff Valve PUMP SHUTOFF VALVE COMPRESSED AIR TO PUMP PUMP SHUTOFF VALVE PUMP SHUTOFF VALVE BACKUP PUMP ADDITIONAL PUMP TUBING PUMP EXHAUST AIR HOSE TUBING EXHAUST SHUTOFF VALVE ELEVATED TANK PROCESS FLUID TUBING Single SPILLSTOP protects multiple pumps with 1 shutoff valve per pump On larger pumps multiple valves could cause reduction in flow due to restriction added to pump exhau...

Страница 12: ...urn Policy Details regarding warranty and return policy are available on Blacoh s website at www Blacoh com PROUDLY MANUFACTURED IN THE USA Blacoh Headquarters 601 Columbia Ave Bldg D Riverside CA 92507 USA 951 342 3100 www Blacoh com Sales Blacoh com ...

Отзывы: