13.0 MAINTENANCE
R599823 - Blackwing Essential mk2013 User Manual
35
ID#
Operating LED
Description
STANDBY /
ON
LAMP
orange LED
WARNING
red LED
Blinking
5/6
-
orange
-
-
Lamp time has reached 2900 hours and/or
prepare to replace the lamp before 4000
hours.
7
-
blinking
orange
continuous
red
1 time
The lamp failed to ignite, restart the
projector after a complete cooldown cycle.
8
2 times
Lamp has shut down during projection,
restart the projector after a complete
cooldown cycle.
9
3 times
Lamp cover is open. Check that the lamp
cover is firmly closed and restart the
projector.
10
-
-
blinking
orange
1 time
Power Supply failed.
11
2 times
Cooling fans stop.
12
3 times
Internal thermal sensor detects
overheating.
13
4 times
External thermal sensor detects
overheating.
14
-
blinking
orange
blinking red
1 time
Startup or drive circuits failed
15
2 times
Communication with drive circuit failed.
16
3 times
Scaler circuit failed
17
4 times
Electrical lens cover failure.
A
BOUT
W
ARNINGS
AND
C
OOL
-D
OWN
M
ODE
After projection or when a warning occurred (cases 7-16), the unit will go through a 1 minute cool-down process
known as the Cool Down mode. This function is to prevent lamp breakage and shortened lamp life but also damage
to the internal components of the projector.
The Cool Down mode is indicated by the blinking red STANDBY/ON led. When in Cool Down mode, the projector
cannot be turned ON. After the Cool Down process is completed, the unit will automatically switch to the Standby
mode indicated by a red STANDBY/ON led.
C
AUTION
When in Cool Down mode, do not pull out the plug from the outlet. Also, do not block the air inlets/exhaust vents by
standing the projector on its end or laying it on its side.