8. Attach the puller plate to the rotor assembly using three (3) of the pump’s 13 mm (1/2”) screws.
PULLER PLATE ON ROTOR ASSEMBLY
9. Support the rotor assembly using a crane, hoist or other suitable lifting device, and position it above the canister 10 cm
(4”) from the front of the outer drive assembly.
ROTOR ASSEMBLY READY FOR LOWERING
10. Slowly lower the rotor assembly into the canister.
NOTE:
During this process, the inner magnets on the rotor assembly
will be strongly attracted to the outer magnets in the outer drive assembly.
ROTOR ASSEMBLY IN PLACE
11. Carefully lift the outer drive assembly (with the tool kit attached) and set it on a workbench, resting on the pump’s foot.
12. Remove the tool rods and puller plate.