1901-a00
21
1. If the pump is equipped with a relief valve, disassemble the relief valve per the instructions in Section 7,
Pump
Disassembly & Repair Processes
.
2. Disassemble pumping chamber per the instructions in Section 7,
Pump Disassembly & Repair Processes
.
3. Remove the casing orifice plug (not found on all configurations) and casing block-off plug.
4. Install the casing orifice plug (if required) behind the DISCHARGE port.
5. If the pump is equipped with a head block-off plug, move it to the DISCHARGE side.
6. Assemble pumping chamber in the new orientation per the instructions in Section 7,
Pump Disassembly & Repair
Processes
.
7. If the pump is equipped with a relief valve, assemble relief valve in the new orientation per instructions in Section 7,
Pump
Disassembly & Repair Processes
.
CASING PLUGS
HEAD BLOCK-OFF PLUG
Содержание IOM E Series
Страница 9: ...1901 a00 9 TEMPERATURE RATINGS...
Страница 10: ...1901 a00 10 MAGNETIC COUPLING STRENGTHS...
Страница 49: ...1901 a00 49 Notes...