STAT-4, STAT-8, AND STAT-24
18
Table 3-2. Sub-channel parameters and factory settings.
No.
Parameter
Function
Available
Factory
Selections
Setting
1
BAUD RATE
Sub-channel
75, 110, 150, 300,
9600
data rate
600, 1200, 2400,
4800, 9600, 19200,
38400 bps
2
DATA BITS
Number of data
5, 6, 7, 8
8
bits in sub-channel
data frame
3
PARITY
Type of parity
Odd, Even
None
used in sub-channel
Space, Mark,
data frame
None
4
STOP BITS
Number of stop
1, 1.5, 2
1
bits in sub-channel
data frame
5
STAT-MUX-TO-
Controls software
On
On
DTE SOFTWARE flow-control
function
Off
FLOW CONTROL
at the local end of
the sub-channel.
When on, see
also Table 3-1,
No. 2, 3.
6
END-TO-END Activates
end-to-end
On
On
SOFTWARE FLOW
software flow control.
Off
CONTROL
When on, see also
Table 3-1, No. 2, 3.
7
END-TO-END DTR
Activates end-to-end
On
On
FLOW CONTROL
hardware flow control
Off
(via DTR line)
8
RTS CONTROL
Enables the transfer
On
Off
PASS
of the RTS state to
Off
the remote DCD line