background image

5

shows ground when the door is open.
• VIOLET WIRE - Positive door trigger (+).

Connect to the door switch circuit wire that

shows +12V when the door is open. This

type of circuit is common on Ford vehicles.
• YELLOW WIRE - +12V Ignition input.

Connect to a main ignition wire at the

ignition switch harness. This wire shows

+12V when the ignition is on and while

cranking. The voltage must not drop when

the car is starting.

NOTE:

Do not connect the alarm module

until the installation is complete. Turn on the

ignition first, then plug in the 9-pin harness

followed by the 3-pin large harness so the

alarm will power up in the disarm state. If

the alarm is plugged in without the ignition

on, it will automatically power up in the

alarming state.

Plug in Connectors

2-Pin Red Connector:

Plug-in port for

LED. Mount LED where it may be easily

seen from either side of the vehicle.

2-Pin Blue Connector:

Plug-in port for

valet switch. Mount switch in an area

accessible from the driver’s seat.

3-Pin Large White Door Lock Connector:

Plug-in connector for door lock harness or

optional door lock relay module.
• BLUE WIRE - unlock output (-) 500mA.
• RED WIRE - not used.
• GREEN WIRE - lock output (-) 500mA.

3-Pin Small White Connector:

Plug-in

port for dual stage shock sensor.

Automatic Output Circuit Breaker

When any (-) output is connected to (+)

constant in error, the system detects the

short circuit automatically and shuts down

that output until the error is corrected

and ignition reset (on-off) is performed.

While the short circuit is detected, the

siren will chirp 4 times and the park lights

will flash 4 times during arm and disarm.

LED will continue to flash 2-9 times

depending on the output shorted until

ignition reset is performed (In both arm

and disarm mode).

Programmable Features
Function

Buttons

1 Chirp 

2 Chirps

Shock Sensor 

3-3-1

Off

On

Arming Chirps

2-1-1

Silent

Normal

Ignition Locking

1-3-2

Off

On

Door Lock Pulse Length

1-3-1

3 Seconds

.75 Second

Door Unlock Pulse

2-2-1

Double

Single

Passive Locking

3-3-2

Off

On

Arming Mode

1-2-3

Active

Passive

Anti-Carjack Activation

2-1-3

Disabled

Enabled

*default settings in 

bold

SHORT CIRCUIT LED INDICATIONS

2 Flashes = Lock Output

3 Flashes = Unlock Output 

4 Flashes = Auxiliary Output

6 Flashes = Starter Defeat Output

7 Flashes = Dome Light Output

8 Flashes = Auxiliary 2 Output

9 Flashes = Passenger Unlock Output

BW2450.qxd  6/11/2009  4:12 PM  Page 5

Содержание BW 2450

Страница 1: ...r Arming if a bad sensor or an open zone is detected the siren will chirp and the parking lights will flash 4 times to indicate a zone is open The system will ignore that input keeping all other areas protected While Armed the system will trigger if The doors are opened The shock sensor detects an impact The hood or trunk is opened When triggered the siren will soundand the parking lights will fla...

Страница 2: ...eature will be cancelled if a door is open when the ignition is turned on This feature may be disabled during installation REMOTE PANIC In the event of an emergency the system s siren can be triggered for 60 seconds to attract attention To activate the Panic Feature press transmitter Button 1 for 3 seconds The siren will sound The parking lights will flash Press button 1 again to exit panic mode F...

Страница 3: ... remote car starter If the output is not connected it still serves as a car finder feature to identify the vehicle in a large parking area OPTIONAL ANTI CARJACK MODE For added security while driving the vehicle the optional anti carjacking feature will activate whenever a door is opened after the ignition has been turned on This feature must be enabled during installation If the anti carjack featu...

Страница 4: ...gative trigger vehicles move the internal jumper next to the relay as shown on the back page diagram NOTE Do not connect to the headlight circuit BLACK WIRE Ground input Connect to a solid chassis ground that is clean and free of paint or dirt RED WIRE 12V Battery input Connect the red fused wire on the main harness to a constant 12V source This wire should be at least a 15 amp supply BROWN WIRE S...

Страница 5: ...module BLUE WIRE unlock output 500mA RED WIRE not used GREEN WIRE lock output 500mA 3 Pin Small White Connector Plug in port for dual stage shock sensor Automatic Output Circuit Breaker When any output is connected to constant in error the system detects the short circuit automatically and shuts down that output until the error is corrected and ignition reset on off is performed While the short ci...

Страница 6: ...en a single and double unlock pulse Passive Locking Allows the doors to automatically lock with Passive Arming Arming Mode Select either manual arming Active or automatic arming Passive Anti Carjacking Activation Enables or disables the anti carjacking feature Test System Arm and disarm system checking that the siren chirps and parking lights are functioning normally as well as Passive Arming and ...

Страница 7: ...f the ignition The siren will chirp once Car 2 will operate normally with both it s transmitters and can now be operated using Car 1 s transmitter as follows Car 2 arm Press buttons 1 4 together on Car 1 transmitter Car 2 disarm Press buttons 2 4 together on Car 1 transmitter Car 2 auxiliary 1 feature Press buttons 3 4 together on Car 1 transmitter DOOR LOCK RELAYS LOCK UNLOCK BLUE GREEN LOCK UNLO...