background image

BLUE

GREEN

RED

LOCK (-) PULSE

+12V CONSTANT OUTPUT

UNLOCK (-) PULSE

RECEIVER

MODULE

VALET SWITCH

LED

STARTER DISABLE INPUT/OUTPUTS

}

WIRING HARNESS

2nd CHANNEL (-) OUTPUT (REQUIRES RELAY)

(+)12V

 PARKING LIGHT (-)OUTPUT (REQUIRES RELAY)

GROUND

12V IGNITION

HORN/SIREN (-) OUTPUT

BROWN

YELLOW

BLACK

GRAY

WHITE

RED

FUSE

RED LED
CONNECTOR

BLUE VALET
CONNECTOR

1  2  3  4  

DIPSWITCH
(INSIDE OF
 MODULE)

4

-

D I P   S W I T C H   P R O G R A M S :

(1) Door lock/unlock pulse ON=.75 sec. OFF= 3 sec.
(2) Door lock/unlock w/ignition. ON=Yes. OFF= No.
(3) Passive Door Locks. ON=Yes. OFF=No.
(4) Passive Arming. ON=Yes. OFF=No.

See programming specifics on page 2, Section 1.

WIRING DIAGRAM

Ig12V

MUST NOT
DROP OUT

during starting

of vehicle.

Содержание BW 752

Страница 1: ...p battery BWS 500 Window roll up WRM 2 Remote starter RAS 101 Power door lock PDL 50 Trunk release TR 100 Relay SPDT Starter disable relay socket BRS 003 5 wire door lock relay socket BRS 008P16 door lock Inverter BW 34516 SPECIFICATIONS Operating voltage 12VDC Neg Ground Code learning 3 Codes Max Current consumption 5 mA max disarmed Door lock unlock output 500 mA Channel 2 output drive 500 mA va...

Страница 2: ... where HIGH HEAT can damage their insulation Always protect the harness wires where they pass through holes in metal panels by using RUBBER GROMMETS 4 Mount the LED Status Indicator in an easily seen location such as the center of the dash or the inside top edge of the driver s or passenger s door Connect the RED 2 pin connector from the LED to the RED 2 pin male plug on the circuit board of the R...

Страница 3: ...ds the LED will turn ON solid Start your vehicle in normal operation 16 The Status Indicators below show the various signals that are produced to indicate a particular condition or situation of the Starter Disable Keyless Entry System 17 Siren Horn Pulsing Output To enable pulsing horn output with the ignition key ON push button 3 on 3 button remote push buttons 1 and 2 simultaneously on 2 button ...

Страница 4: ...White Parking Light Dome Light Output negative output Requires 2 relays for both outputs 3 PIN PLUG IN HARNESS 1 Yellow Unlock Pulse negative output 2 Red Constant 12V output 3 Green Black Lock Pulse negative output 2 PIN OVERRIDE VALET BLUE PLUG IN HARNESS 1 Blue Plug Plug for override valet switch 2 PIN LED RED PLUG IN HARNESS 1 Red Plug Plug for LED Status Indicator PLUG IN STARTER CONNECTORS 1...

Страница 5: ... SIREN OUTPUT BROWN YELLOW BLACK GRAY WHITE RED FUSE RED LED CONNECTOR BLUE VALET CONNECTOR 1 2 3 4 DIPSWITCH INSIDE OF MODULE 4 D I P S W I T C H P R O G R A M S 1 Door lock unlock pulse ON 75 sec OFF 3 sec 2 Door lock unlock w ignition ON Yes OFF No 3 Passive Door Locks ON Yes OFF No 4 Passive Arming ON Yes OFF No See programming specifics on page 2 Section 1 WIRING DIAGRAM Ignition 12V MUST NOT...

Страница 6: ...AY BLUE WIRE FROM ALARM GREEN WIRE FROM ALARM 12V FUSED CONSTANT LOCK UNLOCK If the power trunk release requires a positive pulse to operate use this circuit 2nd CHANNEL AUXILIARY GRAY WIRE 12V POSITIVE OUT TO TRUNK 12V REVERSE POLARITY DIRECTLY TO AD ON ACTUATORS GROUND GROUND REVERSE POLARITY USING FACTORY SYSTEMS FOR NEGATIVE PARKING LIGHTS TRUNK RELEASE CIRCUIT DIAGRAM SWITCH ACTUATOR LOCK UNL...

Страница 7: ... switch is not pressed Repair or replace switch or check long enough to activate the Keyless ignition wire for voltage Entry Flashing output does Bad connection on WHITE Check WHITE wire Connect not work wire or the drive polarity is a SPDT Relay to this wire and wrong for the circuit being apply the opposite polarity to the driven circuit being driven Door locks do not Defective GREEN or BLUE Che...

Отзывы: