![Black Box SW540A-R3 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/black-box/sw540a-r3/sw540a-r3_manual_2761664020.webp)
19
APPENDIX C: Quick Setup Guide
(BACK)
PORT 4
PORT 3
PORT 2
PORT 1
PORT 0
DTE
DCE
J7
U23
U20
J1
W1
VR1
RESET BUTTON
S1
R1
SW
G
SW
F
SW
E
SW
D
SW
C
SW
B
SW
A
SYSTEM SWITCHES
(SWF & SWG)
INDIVIDUAL PORT SWITCHES
STATUS INDICATORS
CH0CH1CH2CH3CH4CH5CH6CH7CH8
PWR
(FRONT)
DTE
DCE
DTE
DCE
DTE
DCE
DTE
DCE
OFF
OFF
OFF
OFF
OFF
OFF
OFF
PORT 4
PORT 3
PORT 2
PORT 1
PORT 0
Switch
Switch
Position Setting
Function
1
ON
Reverts to factory-set attention
string of @ when reset
OFF
Maintains user-set attention string
when reset
2
ON
Limits port name changes and
attention-character changes to
Port 0 only
OFF
All ports can change port names
and attention characters
3
ON
Perform self-test (see
Section 5
)
OFF
Normal operation
4
ON
DCD (RTS) passed through
OFF
DCD (RTS) blocked
5-8
Reserved for future use
Functions and Settings, Switch Bank SWF
Appendix C: Quick Setup Guide
Individual Port Switch Banks
Internal Board Locations
Option
Switch Position Settings
1
2
3
4
5
6
7
8
Baud Rate
110
ON
ON
ON
300
OFF
ON
ON
600
ON
OFF
ON
1200
OFF
OFF
ON
2400
ON
ON
OFF
4800
OFF
ON
OFF
9600
ON
OFF
OFF
19,200
OFF
OFF
OFF
Parity
No Parity
ON
ON
Even Parity
OFF
ON
Odd Parity
ON
OFF
No Parity
OFF
OFF
Data Bits/Word
7
OFF
8
ON
Flow Control
Hardware (DTR/CTS)
ON
Software (X-ON/X-OFF)
OFF
Break Detection
Break to Disconnect
ON
Ignore Breaks