98
PQ-8P, PQ-8S
Table 6-5 (continued). IOGL Graphics Language.
Parameter
Description
Units of
Valid
Measurement
Values
y start
y coordinate of start position
n/300 inch
positive
for lines and boxes
integers;
incl. 0
y end
y coordinate of end position
n/300 inch
positive
for lines and boxes
integers;
incl. 0
y increment
height of one unit of the value
n/300 inch
positive
to be printed in bar or run (line)
integers;
chart
incl. 0