CHAPTER 3: Installation and Setup
3. Installation and Setup
3.1 Introduction
This chapter provides mechanical and electrical installation procedures for the
Fiber Optic Modem. It is a fully assembled standalone unit.
If you encounter a problem, refer to
Chapter 5
for Test and Diagnostics
instructions.
WARNING
Make sure the AC power cord is disconnected before removing the
unit’s cover.
HIGH VOLTAGE - Any adjustment, maintenance, and repair of the
opened instrument under voltage should be thoroughly avoided and
should be carried out only by an experienced technician who is aware of
the hazard involved. Capacitors inside the instrument may remain
charged even after the instrument has been disconnected from its
power supply.
3.2 Site Requirements and Prerequisites
3.2.1 P
OWER
Install the Fiber Optic Modems within 5 ft. (1.5 m) of an easily accessible,
grounded AC outlet capable of furnishing the required supply voltage of the unit
(100, 115, 230 VAC).
To prevent a fire hazard, the (negative) supply line must contain a suitable fuse
or a circuit breaker.
• Allow at least 36 in. (91.4 cm) of frontal clearance for operating and
maintenance accessibility.
• Allow at least 4 in. (10.2 cm) clearance at the rear of the unit for signal lines
and interface cables.
3.2.2 A
MBIENT
R
EQUIREMENTS
The ambient operating temperature of the Fiber Optic Modem is 32 to 122°F (0 to
50°C) at a relative humidity of up to 90%, non-condensing.