background image

19

CHAPTER 3: Installation and Setup

3. Installation and Setup

3.1 Introduction

This chapter provides mechanical and electrical installation procedures for the
Fiber Optic Modem. It is a fully assembled standalone unit.

If you encounter a problem, refer to 

Chapter 5

for Test and Diagnostics

instructions.

WARNING

Make sure the AC power cord is disconnected before removing the
unit’s cover.

HIGH VOLTAGE - Any adjustment, maintenance, and repair of the
opened instrument under voltage should be thoroughly avoided and
should be carried out only by an experienced technician who is aware of
the hazard involved. Capacitors inside the instrument may remain
charged even after the instrument has been disconnected from its
power supply.

3.2 Site Requirements and Prerequisites

3.2.1 P

OWER

Install the Fiber Optic Modems within 5 ft. (1.5 m) of an easily accessible,
grounded AC outlet capable of furnishing the required supply voltage of the unit
(100, 115, 230 VAC).

To prevent a fire hazard, the (negative) supply line must contain a suitable fuse

or a circuit breaker.

• Allow at least 36 in. (91.4 cm) of frontal clearance for operating and

maintenance accessibility. 

• Allow at least 4 in. (10.2 cm) clearance at the rear of the unit for signal lines

and interface cables.

3.2.2 A

MBIENT

R

EQUIREMENTS

The ambient operating temperature of the Fiber Optic Modem is 32 to 122°F (0 to
50°C) at a relative humidity of up to 90%, non-condensing.

Содержание ME555A

Страница 1: ...877 877 BBOX FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox co...

Страница 2: ...perated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measur...

Страница 3: ...ompany may make changes in its technical operations and procedures If any such changes affect the compatibility or use of this device the telephone company is required to give adequate notice of the c...

Страница 4: ...with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility in this case your suppl...

Страница 5: ...may be equipped with a laser diode The laser warning symbol will be attached near the optical transmitter Please observe the following precautions Do not attempt to adjust the laser drive current Do...

Страница 6: ...ato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las in...

Страница 7: ...existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuid...

Страница 8: ...is a registered trademark of International Business Machines Corporation ST is a registered trademark of American Telephone and Telegraph Company Any other trademarks mentioned in this manual are ackn...

Страница 9: ...7 3 Installation and Setup 19 3 1 Introduction 19 3 2 Site Requirements and Prerequisites 19 3 2 1 Power 19 3 2 2 Ambient Requirements 19 3 3 What the Package Includes 20 3 4 What You Need to Supply 2...

Страница 10: ...Digital Loopback RLB Standard V 54 35 5 2 3 Local Digital Loopback DIG Non Standard 36 5 3 Internal BERT Circuit Test 37 5 3 1 Modem Self Test 37 5 3 2 Two BERT Test 38 5 4 Local Analog Loopback Test...

Страница 11: ...r Jumper J3 Set the XMT CLOCK mode INT EXT RCV ASY Default is INT Selector switch SW3 Set the BAUD RATE 19 2 28 8 32 38 4 48 56 57 6 64 72 96 112 115 2 128 144 192 256 kbps Default is 64 kbps Jumper J...

Страница 12: ...VERIFYING PERFORMANCE When data is being transferred observe that the following front panel LEDs light or blink PWR Lights RTS Blinks or Not lit TD Blinks or Not lit RD Lights DCD Lights TEST Not lit...

Страница 13: ...2 5 125 LED fiber Receiver Sensitivity 48 dBm for 850 nm LED 50 dBm for 1300 and 1550 nm laser diode Dynamic Range 36 dB NOTE The ranges specified above were calculated according to the following typi...

Страница 14: ...T 3 Received from receive signal looped back as transmit clock RCV Indicators LEDs Transmit Data TD Receive Data RD Request to Send RTS Data Carrier Detect DCD Test Error ERR Power PWR Loopback mode o...

Страница 15: ...ical signals into optical signals The optical signal is converted back into an electrical signal in compliance with the appropriate interface on the receive end Transmit clock timing is provided eithe...

Страница 16: ...ES Fiber Optics Fiber optic technology permits high immunity against electrical interference such as electromagnetic interference EMI radio frequency interference RFI spikes and differential ground lo...

Страница 17: ...nnectors and power connections from the Fiber Optic Modem s rear panel The AC power connector has an integrated fuse holder The correct rating of the replaceable fuse is printed on the rear panel of t...

Страница 18: ...For this standard the modem compensates for any frequency deviation between the modem and the DTE by adjusting the length of the stop bit of the async character The operation mode of the Async to Sync...

Страница 19: ...C MODEM Tests can be carried out from the remote Fiber Optic Modem by pressing the PATT pushbutton on the remote unit or by connecting a Bit Error Rate Tester which uses the standard 511 bit pattern F...

Страница 20: ...Capacitors inside the instrument may remain charged even after the instrument has been disconnected from its power supply 3 2 Site Requirements and Prerequisites 3 2 1 POWER Install the Fiber Optic M...

Страница 21: ...3 1 WARNING Only authorized and qualified service personnel should access the inside of the equipment To avoid accidental electric shock always disconnect the interface cables and the power cord befor...

Страница 22: ...tlet 2 Release the two rear panel screws and use them as levers to slide out the printed circuit board interior To set switches and jumpers 1 Identify the switches according to the configuration diagr...

Страница 23: ...is high J3 Selects the transmit EXT XMT CLK timing signal from either INT INT internal clock external RCV clock or receive clock ASY J4 Selects the delay time 0 RTS CTS in ms between RTS 9 9 ms DLY m...

Страница 24: ...sis chassis ground In DIS Ground position the signal ground is isolated from the chassis ground SW3 Selects the data rate 19 2 28 8 32 64 BAUD RATE 38 4 48 56 57 6 kbps 64 72 96 112 115 2 128 144 192...

Страница 25: ...24 SYNC ASYNC FIBER OPTIC MODEM Figure 3 1 Fiber Optic Modem Configuration Diagram...

Страница 26: ...ODD 1 1 5 2 10 EVEN 11 1 8 NONE 1 1 5 2 10 11 1 8 ODD EVEN 1 1 5 2 11 To return the Fiber Optic Modem to its case Slide the PCB interior back into the case Screw in the two rear panel screws to affix...

Страница 27: ...mote unit connect the transmit fiber to RX and the receive fiber to TX Connecting the DTE NOTE We recommend using a shielded twisted pair cable between the Fiber Optic Modem and the DTE mainly for hig...

Страница 28: ...ent and voltage rating as indicated on the Modem Do not short circuit fuse holders Whenever it is likely that the protection offered by fuses has been impaired make the Modem inoperative and secure it...

Страница 29: ...check all of the installation procedures given in Chapter 3 before attempting to operate the Fiber Optic Modem 4 2 Front Panel Controls and Indicators All pushbutton switches and LED indicators are lo...

Страница 30: ...ransmitted Flickers when data is being transmitted 4 RD Yellow LED On when steady SPACE is being received Flickers when data is being received 5 DCD Yellow LED On when a valid receive signal is presen...

Страница 31: ...remote Fiber Optic Modem to loop received data and clock signal back to its transmitter see Figure 5 2 This loopback may also be activated from the DTE when the RLB strap is set to EN 11 PATT Pushbut...

Страница 32: ...ink between the two DTEs Press the PATT pushbutton on the Fiber Optic Modem s front panel If any errors are encountered the SQ LED will dim continuously for continuous errors or blink for intermittent...

Страница 33: ...PTIC MODEM 4 4 2 RUNNING DIAGNOSTIC LOOPS Refer to Chapter 5 for more information on running diagnostic loops 4 4 3 POWER OFF PROCEDURE To power down the Fiber Optic Modem remove the AC power cord fro...

Страница 34: ...511 bit pseudo random pattern If it encounters any errors the ERR LED lights You can run the test in local analog loopback in remote digital loopback or in normal point to point operation opposite a...

Страница 35: ...ed for the test Do not run any tests using faulty equipment Make sure that all units are powered ON and are configured correctly 5 2 1 LOCAL TEST LOCAL ANALOG LOOPBACK LLB STANDARD V 54 The Local Anal...

Страница 36: ...the fault To identify a problem in the communication line perform the LLB loopback at the remote end of the line If both LLB tests are error free the fault is in the communication link or in the line...

Страница 37: ...then the line or line circuits on one side of the line are not functioning properly 5 2 3 LOCAL DIGITAL LOOPBACK DIG NON STANDARD This test loops the received data back to the remote Fiber Optic Modem...

Страница 38: ...mitted is a proprietary random pattern The pattern transmitted by the BERT can be received by another Fiber Optic Modem a two BERT test or looped back to the BERT for comparison modem self test When u...

Страница 39: ...ntermittent errors the Fiber Optic Modem is faulty and should be replaced If the test executes correctly restore all pushbuttons and jumpers to their normal position Figure 5 4 Fiber Optic Modem Self...

Страница 40: ...its own receiver 2 Verify that the data terminal equipment is operating properly and can be used for the test If it is faulty call a technician to replace the unit 3 Execute the test using one of the...

Страница 41: ...Tests see Section 5 5 LOOPBACK FUNCTION The Local Loopback command is activated by the DTE interface or by the pushbutton on the front panel The Fiber Optic Modem sends MARK level or OFF state to the...

Страница 42: ...xplained in Section 5 3 3 If Step 2 indicates a fault and if the modem test described in Section 5 4 was successful for both the local and remote modems the line circuits are not operating properly 5...

Страница 43: ...ed Data 2 BA A Serial digital data from DTE The data transitions must occur on the rising edge of the transmit clock in sync applications Received Data 3 BB A Serial digital data at the output of the...

Страница 44: ...23 CD B Carrier Detect 8 CF A A positive level from the Fiber Optic 10 CF B Modem except when a loss of the received signal is detected or when Data Set Ready is negative External Transmit 24 DA A A...

Страница 45: ...Loop 18 LL A control signal which when on instructs the Fiber Optic Modem to send a Local Analog Loopback V 54 Loop 3 Remote Digital 21 RL A control signal which when on Loop instructs the Fiber Opti...

Страница 46: ...lone and Frame Pin Circuit Pin Circuit Protective Ground 1 Shield 1 Signal Ground 19 37 7 AB 20 Transmitted Data 22 SD B 2 BA A 4 SD A 14 BA B Received Data 6 RD A 3 BB A 24 RD B 16 BB B Request to Se...

Страница 47: ...on RS 449 RS 422 423 EIA 530 37 Pin DB25 Female Standalone and Frame Pin Circuit Pin Circuit External Transmit 17 TT A 24 DA A Clock 35 TT B 11 DA B Transmit Clock 5 ST A 15 DB A 23 ST B 12 DB B Recei...

Страница 48: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2000 Black Box Corporation All rights reserved...

Отзывы: