15
CHAPTER 3: Configuration
Table 3-5. Remote Digital Loopback Test.
S1-8
Setting
On
Response to RDL request enabled
Off
Response to RDL request disabled
3.1.3 C
ONFIGURATION
S
WITCH
S2
The 2-Wire IDSL Line Driver Rack Cards may be configured by a menu-driven
software system when used with the Managed Micro Rack Control Module,
VT100™ (part number RM262C) or Managed Micro Rack SNMP/HTTP Card,
SNMP (part number RM261C-SNMP). In order to configure the 2-Wire IDSL
Line Driver Rack Card by software commands, you must set its control port
address.
The control port address is defined by a two-digit decimal number. Switches S2-1
through S2-4 define the least significant digit or the “ones” digit, and Switches S2-5
through S2-7 define the “tens” digit. Valid addresses are 0 through 79. Use
Table 3-6 and the instructions that follow the table to set the control port to the
desired address.
Table 3-6. S2 summary.
Address
Switch S2 Settings
Digit
1
2
3
4
5
6
7
8
Default 0
ON
ON
ON
ON
ON
ON
ON
ON
1
OFF
ON
ON
ON
OFF
ON
ON
ON
2
ON
OFF
ON
ON
ON
OFF
ON
ON
3
OFF
OFF
ON
ON
OFF
OFF
ON
ON
4
ON
ON
OFF
ON
ON
ON
OFF
ON
5
OFF
ON
OFF
ON
OFF
ON
OFF
ON
6
ON
OFF
OFF
ON
ON
OFF
OFF
ON
7
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
8
ON
ON
ON
ON
N/A/
N/A
N/A
N/A
9
OFF
ON
ON
OFF
N/A
N/A
N/A
ON