V.92 DIALUP 2-WIRE OR 4-WIRE LEASED-LINE DATA/FAX MODEM AT COMMANDS GUIDE
22
2.5 Callback Security Commands
Command:
#CBN
n
=
[-]x
Store Callback Number
Values:
n
= 01–30
x
= dialing string
Default:
None
Description:
Stores the callback dialing string
x
in a memory location. The dialing
string can include the digits 0 through 9 and any of the following
characters:
#, *, comma (,), semicolon (;), W, A, B, C, and D.
Up to 30 characters can be used. For example: AT#CBN01=9,
16127853000.
If the optional - character precedes the dialing string, and the caller
appends the same character to the password, the caller is immediately
connected.
Command:
#CBP
n
=
x
Store Callback Password
Values:
n
= 01–30
x
= password (6–10 characters)
Default:
None
Description:
Stores callback security password
x
in memory location
y
. The password
must have 6 to 10 characters. For example: AT#CBP01=gilamep.
NOTE
A direct connect password may not end with a hyphen (-).
Command:
#DB
n
Callback Enable/Disable
Values:
n
= 0 or 1
Default:
0
Description:
Enables or disables callback security. When callback security is enabled,
phone number memory locations 0–4, used for quick dialing and DTR
dialing, become unavailable and are replaced by callback security
memory locations 1–30. The phone number memory locations and
their contents are restored when callback security is disabled.
#DB0
Disables callback security.
#DB1
Enables callback security.