Using iView for Management

iView

is a cross-platform network management application for Black Box

intelligent networking devices.  It features a graphic user interface (GUI) and
gives network managers the ability to monitor and control Black Box prod-
ucts from a variety of platforms.  

iView

can also function as a snap-in mod-

ule for many SNMP-based applications.

S

Y S T E M

R

E Q U I R E M E N T S

To run 

iView for Media Converter System II 

chassis, the management PC

must be equipped with the following:

• 20 MB free disk space, 32 MB RAM as well as one of the following 

operating systems:

•  Windows 95/98/NT/2000 (standalone or with HP OpenView™)

•  HP-UX™ and OpenView

D

I S P L A Y

R

E Q U I R E M E N T S

iView

requires the following display settings:

•  Color setting of at least 64K (higher than 256 colors)
•  Monitor resolution of at least 800 x 600

I

N S T A L L I N G A N D

U

S I N G I

V

I E W

Please consult the 

iView

CD for assistance in installing and launching

iView

.  See the 

iView 

help file for assistance in configuring and managing

your Black Box 

SNMP Modules

.

If Using iView with HP OpenView

During the installation, 

iView

will ask if HP OpenView is installed on the

management PC.  Click 

Yes

to integrate the appropriate files.  You can also

manually copy the file MC.REG into the appropriate OpenView resource
directory on the management PC (usually C:\openview\registration\c).

Once in OpenView, highlight the media converter icon and select the

media converter; OpenView will then launch 

iView

.

If Not Using iView

If using an application other than 

iView 

for management, you will need

to integrate the SNMP vendor files (a.k.a. MIBs) into your application.

The SNMP agent uses the following MIB files, which can be found in

the directory root on the CD included with the 

Media Converter System II

:

8

MIB-I/MIB-II

SNMP statistics, transport protocol orientated statistics

(IP, ICMP, UDP, TCP), information collected on frames sent to/from
all MAC interfaces inside the agent.

MCIMC.MIB

Enterprise-specific information for the agent.  For

example, configuration information, port type information, link 
status, etc.

U

S I N G

M I B   C O M P I L E R

The majority of management packages have a function known as a 

MIB COMPILER.  This function reads in the MIB information and converts it
to machine-readable format.  Refer to your management software’s docu-
mentation for information on how MIB files are integrated into the software.

U

S I N G

M I B   B R O W S E R

The information held within the management can be retrieved by using

the MIB BROWSER function of the management software.

In addition to integrating the MIB information, you need to ensure that

the community strings configured by the SNMP agent are also the ones
used by the management software.  Failure to do this will result in the
inability to SET, or retrieve, MIB variables.

Once the MIB compile is complete and the management software has

“discovered” the 

Media Converter System II 

chassis, complete the follow-

ing steps using the MIB BROWSER to ensure the MIB files are installed
correctly and the 

Media Converter System II

is responding to the SNMP:

1. From the SYSTEM group of MIB-I/MIB-II, 

GET

the variable 

sysDescr.0

.

This should return the following information:

Black Box SNMP-Manageable Media Converter

2. From the SYSTEM group of MIB-I/MIB-II, 

SET

the variable 

sysContact.0

to

your name.

3. From the SNMP Media Converter group of the MCIMC.MIB, 

GET

the

value of the variable 

productName.1

.  A text value corresponding to the

type of chassis in use should appear.

If any of the above fails, please note the error message, the type of

management software being used and call Black Box technical support at
724-746-5500 for assistance.

9

Содержание LMC5100A

Страница 1: ...supply 1 18 8 S Sl lo ot t R Ra ac ck km mo ou un nt t C Ch ha as ss si is s LMC5104A LMC5105A DC and LMC5164A 60 watt is a 3U high rackmountable chassis that features 18 slots for installing SNMP Mo...

Страница 2: ......

Страница 3: ...ight through twisted pair cable into the port labeled SNMP on the Media Converter System II chassis Plug the other end of the cable into a device e g switch hub etc in your existing 10 Mbps Ethernet n...

Страница 4: ......

Страница 5: ...priate port on your computer terminal Set your computer terminal for VT 100 emulation The serial port on the computer terminal should be set for 3 38 8 4 4K K b ba au ud d 8 8 d da at ta a b bi it ts...

Страница 6: ......

Страница 7: ...ving Trap Destinations To remove all trap destinations press K You will then be asked if you really want to remove all trap destinations Press Y to continue Press N to abort Press Enter Password Prote...

Страница 8: ......

Страница 9: ...ure that the community strings configured by the SNMP agent are also the ones used by the management software Failure to do this will result in the inability to SET or retrieve MIB variables Once the...

Страница 10: ......

Страница 11: ...e chassis while allowing media conver sion to continue To reset the management take a slender non conductive object about the width of a paper clip insert it into the hole of the chassis and press the...

Страница 12: ......

Страница 13: ...sing Power 2 Slot Chassis AC Input Load 100 240V 10 VAC 0 2 0 1 Amps DC Input Load 48 10 VDC 0 4 Amps 8 Slot Chassis AC Input Load 100 240V 10 VAC 0 5 0 2 Amps DC Input Load 48 10 VDC 1 0 Amps 18 Slot...

Страница 14: ...u nt to by d rt o n...

Страница 15: ...environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communi...

Страница 16: ...P...

Отзывы: