Black Box LMC5100A Скачать руководство пользователя страница 2

I

N S T A L L I N G

2  

A N D

8 - S

L O T

D

E S K T O P

C

H A S S I S

Be sure that the unit is placed on a suitable flat surface, leaving some

space at the back of the unit to accommodate the exhaust fans.  Attach
the cables between the chassis and each device that will be interconnect-
ed, then plug the chassis into a reliable, filtered power source.

I

N S T A L L I N G

1 8 - S

L O T

R

A C K M O U N T

C

H A S S I S

To install an 

18-slot Rackmount

chassis, have four #10 screws and four

clip nuts available.  (Hardware may vary depending on rack type.)  The
rest of the hardware is supplied with the unit.

First, mount the RETMA mounting ears to the chassis with the supplied

hardware.  Then locate a suitable location in the rack for installation and
secure the clip-nuts onto the mounting rails.  Use the screws to attach the
chassis to the rack.  Finally, attach the cables between the chassis and
each device that will be interconnected, then plug the chassis into a reli-
able, filtered power source.

Power Limitations

Due to the high power demands of 

10/100 modules

and 

Gigabit 

modules 

you cannot fully populate some 

18-Slot

chassis with some 

SNMP

Modules

.  The chart below shows the maximum number of modules each

power supply can accommodate.

If you wish to use these modules in combinations, please consult Black

Box Technical Support for more information. 

2

I N S T A L L A T I O N

T I P

When testing, Black Box recommends you test your module first in an

unmanaged

environment.  To do this, disable management (i.e., move

the “SNMP” switch to the OFF position), follow the unmanaged configu-
ration instructions (see application module manual), then install the unit,
connect the cables and test the LEDs.  When finished, re-activate man-
agement and configure the unit via the software.

A) Connect the equipment to a 48V DC supply source that is electrically 

isolated form the alternating current source.  The 48V DC source is to

be connected to a 48V DC SELV source.
B) Input wiring to terminal block must be routed and secured in such a 

manner that it is protected from damage and stress.  Do not route

wiring past sharp edges or moving parts.
C) A readily accessible disconnect device, with a 3mm minimum contact 

gap, shall be incorporated in the fixed wiring.

3) Grounding: reliable earthing of this equipment must be maintained.

Particular attention should be given to supply connections when connect-
ing to power strips, rather than direct connections to the branch circuit.

W

A R R A N T Y

Please contact Black Box for complete warranty information.

F

E D E R A L

C

O M M U N I C A T I O N S

C

O M M I S S I O N

R

A D I O

F

R E Q U E N C Y

I

N T E R F E R E N C E

S

T A T E M E N T

This equipment has been tested and found to comply with the limits for a Class B com-

puting device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment.  This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.  Operation of this equipment in a residential
area is likely to cause harmful interference in which the user will be required to correct the
interference at his own expense.

This digital apparatus does not exceed the Class B limits for radio noise emission from

digital apparatus set out in the Radio Interference Regulation of the Canadian Department of
Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites

applicables aux appareils numériques de classe B prescrites dans le Règlement sur le brouil-
lage radioélectrique publié par le ministère des Communications du Canada.

S

A F E T Y

C

E R T I F I C A T I O N S

UL:

Listed to UL1950 and CSA 22.2, No.  950, Safety of Information
Technology Equipment, Including Electrical Business Equipment.

CE:

The products described herein comply with the Council Directive on
Electromagnetic Compatibility (89/336/EEC ) and the Council
Directive on Electrical Equipment Designed for use within Certain
Voltage Limits (73/23/EEC).  Certified to EN 60950, Safety of
Information Technology Equipment, Including Electrical Business
Equipment.  For further details, contact Black Box.

15

M

A X I M U M

M

O D U L E S F O R

1 8 - S

L O T

C

H A S S I S

M

M

O

OD

DU

ULLE

E

6

60

0W

W  A

AC

C

1

11

10

0W

W  A

AC

C  

A

AN

ND

D

D

DC

C

10/100 TX/FX

14

18

Gigabit TX/LX and TX/SX

10

13

N O T E

The dial and switch, located on the backplane of each chassis, are
factory configured; DO NOT CHANGE settings. 

Содержание LMC5100A

Страница 1: ...supply 1 18 8 S Sl lo ot t R Ra ac ck km mo ou un nt t C Ch ha as ss si is s LMC5104A LMC5105A DC and LMC5164A 60 watt is a 3U high rackmountable chassis that features 18 slots for installing SNMP Mo...

Страница 2: ......

Страница 3: ...ight through twisted pair cable into the port labeled SNMP on the Media Converter System II chassis Plug the other end of the cable into a device e g switch hub etc in your existing 10 Mbps Ethernet n...

Страница 4: ......

Страница 5: ...priate port on your computer terminal Set your computer terminal for VT 100 emulation The serial port on the computer terminal should be set for 3 38 8 4 4K K b ba au ud d 8 8 d da at ta a b bi it ts...

Страница 6: ......

Страница 7: ...ving Trap Destinations To remove all trap destinations press K You will then be asked if you really want to remove all trap destinations Press Y to continue Press N to abort Press Enter Password Prote...

Страница 8: ......

Страница 9: ...ure that the community strings configured by the SNMP agent are also the ones used by the management software Failure to do this will result in the inability to SET or retrieve MIB variables Once the...

Страница 10: ......

Страница 11: ...e chassis while allowing media conver sion to continue To reset the management take a slender non conductive object about the width of a paper clip insert it into the hole of the chassis and press the...

Страница 12: ......

Страница 13: ...sing Power 2 Slot Chassis AC Input Load 100 240V 10 VAC 0 2 0 1 Amps DC Input Load 48 10 VDC 0 4 Amps 8 Slot Chassis AC Input Load 100 240V 10 VAC 0 5 0 2 Amps DC Input Load 48 10 VDC 1 0 Amps 18 Slot...

Страница 14: ...u nt to by d rt o n...

Страница 15: ...environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communi...

Страница 16: ...P...

Отзывы: