In addition to assigning an IP address and subnet mask, the latter two

methods will also allow you to create community strings, assign access
rights, configure traps and more.  However, 

HUBCTRL32

offers more

options than configuring via the serial port (e.g., you can select 

which

traps

to assign with 

HUBCTRL32

).

After assigning a 

Media Converter System II 

chassis an IP address, you

can use 

iiV

Viie

ew

w

or another SNMP-compatible Network Management

System (NMS) to remotely configure, monitor and manage the 

SNMP

Modules

installed within the unit (see page 6 of this guide for more infor-

mation).

Management of the 

Media Converter System II

may be disabled by

moving the switch labeled “SNMP” to “OFF.”  By doing this, individual
modules will no longer be managed, but the SNMP agent will continue to
communicate.  As the modules are now unmanaged, all settings for the
modules revert to those established by hardware jumpers or switches.
Turning management back on will return the modules to management
control and any settings previously established via software.

A

B O U T

D H C P

There is a DHCP client in the 

Media Converter System II

chassis.  By

default, the DHCP client is disabled.  If a DHCP server is present on the
network,  the DHCP client will initiate a dialogue with the server during the
boot up sequence.  The server will then issue an IP address to the 

Media

Converter System II 

chassis.  Once the new IP address is received, 

Media

Converter System II

will reboot so that the new IP address will take effect.

See the 

About Serial Port Configuration

section for Enable/Disable informa-

tion.

If there is no DHCP server on the network, use 

HUBCTRL32

or serial

configuration to manually set the IP addresses.

A

B O U T

H U B C T R L 3 2

HUBCTRL32

(Hub Control 32) is an in-band configuration utility that

lets users quickly and easily complete the first stages of SNMP configura-
tion for Black Box SNMP-manageable devices.

Tasks 

HUBCTRL32

can perform include:

•  

setting the IP address, subnet mask and default gateway

•  

defining the community strings and SNMP traps

In addition to the above functions, 

HUBCTRL32

offers an authorized IP

address system and access restriction to MIB (

Management Information

Base

) groups supported by Black Box manageable devices.  These extra lay-

ers of security are purely optional and do not affect SNMP compatibility in
any way.

4

Black Box Customer Service

Call: (724) 746-5500

Phone orders 24 hours a day,  7:00 AM

Monday to midnight Friday; 8:00 AM to 4:00 PM Saturday (EST)

Fax:  (724) 746-0746

or in North America 

1-800-321-0746

Mail order:

Black Box Corporation, 1000 Park Drive, Lawrence,

PA 15055-1018

Technical Support and fax orders 24 hours a day. 

S

P E C I F I C A T I O N S

Environmental

Operating Temperature

: 32° - 104° F (0° - 40° C)

Storage Temperature

: 0° - 160° F (-20° - 70° C)

Humidity

:  5 - 95% (non-condensing)

Power

2-Slot Chassis

:

AC Input Load: 100-240V ±10% VAC, 0.2/0.1 Amps.
DC Input Load: -48 ±10% VDC, 0.4 Amps

8-Slot Chassis

:

AC Input Load: 100-240V ±10% VAC, 0.5/0.2 Amps.
DC Input Load: -48 ±10% VDC, 1.0 Amps

18-Slot Chassis

:

AC Input Load (60W) : 

100-240 VAC ±10%, 0.8/0.4A max.

AC Input Load (110W) :

100-240 VAC ±10%, 1.2/0.6A max.

Dimensions

2-Slot Chassis

:

2”H x 8.9”L x 5.0”D (5.1cm x 22.6cm x 12.6 cm)
2.7 lbs (1.3 kg)

8-Slot Chassis

:

4.6”H x 8.7”W x 7”D (11.6cm x 22.1cm x 17.8cm)
6.2 lbs (2.8 kg)

18-Slot Chassis

: 4.6” H x 17.4” W x 9.1” D (11.6cm H x 44.3cm W x 

23.2cm D) 12.9 lbs (5.9 kg)

Heat Generation

2-Slot Chassis

:

70 BTU/hr. maximum

8-Slot Chassis

:

170 BTU/hr. maximum

18-Slot Chassis

:

400 BTU/hr. maximum

13

Содержание LMC5100A

Страница 1: ...supply 1 18 8 S Sl lo ot t R Ra ac ck km mo ou un nt t C Ch ha as ss si is s LMC5104A LMC5105A DC and LMC5164A 60 watt is a 3U high rackmountable chassis that features 18 slots for installing SNMP Mo...

Страница 2: ......

Страница 3: ...ight through twisted pair cable into the port labeled SNMP on the Media Converter System II chassis Plug the other end of the cable into a device e g switch hub etc in your existing 10 Mbps Ethernet n...

Страница 4: ......

Страница 5: ...priate port on your computer terminal Set your computer terminal for VT 100 emulation The serial port on the computer terminal should be set for 3 38 8 4 4K K b ba au ud d 8 8 d da at ta a b bi it ts...

Страница 6: ......

Страница 7: ...ving Trap Destinations To remove all trap destinations press K You will then be asked if you really want to remove all trap destinations Press Y to continue Press N to abort Press Enter Password Prote...

Страница 8: ......

Страница 9: ...ure that the community strings configured by the SNMP agent are also the ones used by the management software Failure to do this will result in the inability to SET or retrieve MIB variables Once the...

Страница 10: ......

Страница 11: ...e chassis while allowing media conver sion to continue To reset the management take a slender non conductive object about the width of a paper clip insert it into the hole of the chassis and press the...

Страница 12: ......

Страница 13: ...sing Power 2 Slot Chassis AC Input Load 100 240V 10 VAC 0 2 0 1 Amps DC Input Load 48 10 VDC 0 4 Amps 8 Slot Chassis AC Input Load 100 240V 10 VAC 0 5 0 2 Amps DC Input Load 48 10 VDC 1 0 Amps 18 Slot...

Страница 14: ...u nt to by d rt o n...

Страница 15: ...environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communi...

Страница 16: ...P...

Отзывы: