LGB5128A User Manual
120
Parameter description:
Port :
The Port column shows the list of ports for which you can configure GARP settings. There
are 2 types configuration settings that can be configured on per port bases.
•
Timer Values
•
Applicantion
•
Attribute Type
•
GARP Applicant
Timer Values :
To set the GARP join timer, leave timer, and leave all timers, unit is Micro-second.
Three different timers can be configured on this page:
Join Timer :
The default value for Join timer is 200 ms.
Leave Timer :
The range of values for Leave Time is 600–1000 ms. The default
value for Leave Timer is 600 ms.
Leave All Timer :
The default value for Leave All Timer is 10000 ms
Application :
Currently the only supported application is GVRP.
Attribute Type :
Currently the only supported Attribute Type is VLAN.
GARP Applicant
This configuration is used to configure the Applicant state machine behavior for GARP on a
particular port locally.
•
normal-participant:
In this mode the Applicant state machine will operate normally in
GARP protocol exchanges.
•
non-participant:
In this mode the Applicant state machine will not participate in the
protocol operation.
The default configuration is normal participant.
Buttons:
Save
– Click to save changes.
Reset-
Click to undo any changes made locally and revert to previously saved
values.
Содержание LGB5124A
Страница 9: ...ix DELETE THIS PAGE...
Страница 10: ......
Страница 147: ...137 If you select the scheduler mode with wighted then the screen will change as the figure...