CHAPTER 11: ACCESS CONTROL
Logging: Specify the logging operation of this port. The allowed values are:
- Enabled: Frames received on the port are stored in the System Log.
- Disabled: Frames received on the port are not logged.
The default value is “Disabled.”
NOTE: The System Log memory size and logging rate is limited.
Shutdown: Specify the shut down operation of this port. The allowed values are:
- Enabled: If a frame is received on the port, the port will be disabled.
- Disabled: Port shut down is disabled.
The default value is “Disabled.”
State: Specify the state of this port. The allowed values are:
- Enabled: Reopen ports by changing the volatile port configuration of the ACL user module.
- Disabled: Close ports by changing the volatile port configuration of the ACL user module.
The default value is “Enabled.”
Counter: Counts the number of frames that match this ACE.
Buttons:
Refresh, clear: Click to refresh the ACL Port Configuration or clear them manually.
Apply: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values.
11.2 RATE LIMITERS
This section describes how to configure the switch’s ACL Rate Limiter parameters. The Rate Limiter Level from 1 to 16 allow userss
to set the rate limiter value in units of pps.
WEB INTERFACE
To configure ACL Rate Limiter in the web interface:
1. Click Access Control and Rate Limiters.
2. Specify the Rate field, Unit.
3. Click Apply to save the setting
4. To cancel the setting, click the reset button. It will revert to previously saved values.