240
1.877.877.2269
BLACKBOX.COM
NEED HELP?
LEAVE THE TECH TO US
LIVE 24/7
TECHNICAL
SUPPORT
1.877.877.2269
CHAPTER 12: SYSTEM MANAGEMENT
To set an alternate default configuration:
Check Load On Erase
Click Apply.
NOTE: Before selecting Load On Erase, ensure you have tested your alternate default configuration by clicking Restore.
If your alternate default configuration causes the console server to become unbootable, recover your unit to factory settings.
If the configuration is stored on an external USB storage device, unplug the storage device and reset to factory defaults as per
Section 12.1.
If the configuration is stored on an internal USB storage device, reset to factory defaults using a specially-prepared USB storage
device.
This specially-prepared USB storage device:
Must be formatted with a Windows FAT32/VFAT file system on the first partition or the entire disk.
Most USB thumb drives are sold already formatted this way.
The file system must have the volume label OPG_DEFAULT.
Insert this USB storage device into an external USB port on the console server and reset to factory defaults as per Section 12.1.
After recovering your console server, ensure the problematic configuration is no longer selected for Load On Erase.
12.5 DELAYED CONFIGURATION COMMIT
This mode allows the grouping or queuing of configuration changes and the simultaneous application of these changes to a
specific device. For example, changes to authentication methods or user accounts may be grouped and run once to minimize
system downtime. To enable:
Navigate to System > Administration.
Check the Delayed Config Commits checkbox.
FIGURE 12-8.
Click Apply.