Chapter 15: User Commands
15.9.3 D
EFINING THE
V.25
BIS
L
INE
T
ERMINATOR
C
HARACTER
S-Register S64 is used to identify to the ISDN TA/V the line terminator
character used by the DTE while in V.25bis command mode:
S64=0
Carriage line feed characters.
S64=1
Carriage return character.
S64=2
Line feed character.
15.10 The ISDN TA/V’s Response to Valid and Invalid Commands
When the ISDN TA/V is configured to respond to AT commands, using one
of the Q command settings described in
Section 13.5
, it will respond to valid
and invalid commands according to the value of S-Register S84.
S84=0
Normal response codes are enabled.
S84=1
The ISDN TA/V will respond to an AT command with OK,
irrespective of whether the AT command was valid or not.
S84=2
The ISDN TA/V will respond to any AT command with OK,
but will not implement those that would normally result in a
change to a configuration.
15.11 Audible Alert Control
The
&B
command is used to determine whether a buzzer is sounded
whenever the ISDN TA/V’s front-panel LCD displays an important message.
&B0
The buzzer is disabled.
&B1
An audible alert will sound to bring attention to call progress
events displayed on the LCD.
&B2
An audible alert will sound to bring your attention to all
events displayed on the LCD.