CHAPTER 6: RS-232 CONTROL
6.3.5 HDCP COMPLIANCE
TABLE 6-5. HDCP COMPLIANCE COMMANDS
COMMAND
FUNCTION
FEEDBACK EXAMPLE
/%[Y]/[X]:[Z]
HDCP management command.
Y=O is for output;
X=1–8 is the number of the port, if the
X=ALL, it means all ports;
Z is for HDCP compliant status, the value may be 1 (HDCP compliant) or 0
(not HDCP compliant).
/%[Y]/[X]:[Z].
%0801.
Auto HDCP management, activate carrier native mode
%0801
%9973.
Query the HDCP status of the input signals.
In 01 02 03 04: HDCP Y N Y N
In 05 06 07 08: HDCP Y Y Y N
%9974.
Query the HDCP status of the output signals.
Out 01 02 03 04: HDCP Y Y Y Y
Out 05 06 07 08: HDCP Y Y Y Y!
6.3.6 EDID CONFIGURATION
The DIP switch status should be set as 1111 to enable Software EDID management mode: RS-232 control or Web-based GUI
control.
TABLE 6-6. EDID CONFIGURATION COMMANDS
COMMAND
FUNCTION
FEEDBACK EXAMPLE
EDIDH[x]B[y].
Input port [y] learns the EDID from output port [x].
If the EDID data is available and the audio part supports not only PCM mode, then force-set
it to support PCM mode only. If the EDID data is not available, then set it as initialized EDID
data.
EDIDH[x]B[y]
EDIDPCM[x].
Set the audio part of input port [x] to PCM format in EDID database.
EDIDPCM[x]
EDIDG[x].
Get EDID data from output [x] and display the output port number.
Hexadecimal EDID data and
carriage return character
EDIDMInit.
Restore the factory default EDID data for each input.
EDIDMInit.
EDIDM[X]B[Y].
Manually EDID switching. Enable input [Y] to learn the EDID data of output [X]. If the EDID
data is not available, then set it as initialized EDID data.
EDIDM[X]B[Y]
EDID/[x]/[y].
Set the EDID data of input port [x] to built-in EDID No. [y]. [y]=0–11, correspond to the 12
embedded EDID data separately
EDID/[x]/[y]
EDIDUpgrade[x].
Switch Upgrade EDID data via the RS232 port. X represents the input port, and x=9
represents all input ports. When the switcher receives the command, it will show a message
to prompt you to send EDID file (.bin file). Operations will be canceled after 10 seconds.
Please send the EDID
file EDID Upgrade OK!
GetInPortEDID [X]
Get the EDID data of input [x], [x]=1–8
%9979.
Get the DIP switch status
EDID RS232 GUI
CONTROL 1111