CHAPTER 6: RS-232 CONTROL
6.3 RS-232 COMMUNICATION COMMANDS
Case-sensitive
“[“, “]”in the commands are for easy recognition only and not necessary in real operations. Other symbols including “.”, “,”, “/”, “%”, “;”,
“^”.are parts of the commands
Feedback listed in the column “Feedback Example” are only for reference, feedback may vary according to different operations
Dial the EDID switcher to “1111”before sending commands pertaining to software EDID management (with gray background)
Baud rate: 9600
Data bit: 8
Stop bit: 1
Parity bit: None
6.3.1 SYSTEM COMMANDS
TABLE 6-1. SYSTEM COMMANDS
COMMAND FUNCTION
FEEDBACK EXAMPLE
/*Type;
Query the model
AVS-HDMI2-8X8
/^Version;
Query the version of firmware
VX.X.X
Demo.
Switch to the“demo” mode, convert input and output in turn like1B1, 1B2, …4B3, 4B4,
1B1… and so on. The switching interval is 2 seconds.
EDID: Demo Mode
AV:01->01
AV:01->02
AV:01->03
AV:01->04
AV:02->01
…
Normal Mode
Undo.
To cancel the current operation
Undo Ok!
PWON.
Work in normal mode
PWON
PWOFF.
Enter into standby mode, send the “PWON.” to start
PWOFF
STANDBY.
Enter into standby mode, press other buttons or send other commands to start
STANDBY
%9962.
Query the power status
STANDBY/PWOFF/PWON
%9964.
Query the IP address
IP:XXX.XXX.X.XXX
%0911.
Reset to factory default
Factory Default