Page 29
724-746-5500 | blackbox.com
Chapter 4: Operation
4.4 RS-232 Control Operation
RS-232 can be transmitted bi-directionally between AVSC-5DA1-HDB and AVS-HDB-RX,
so you can control a third-party RS-232 device locally or control the AVSC-5DA1-HDB
remotely. When you want to control a third party RS-232 device, set the baud rate of
this device to 2400, 4800, 9600, 19200, 38400, 57600, or 115200.
4.4.1 RS-232 Control Software Installation
• Installation: Copy the control software file to the computer connected to the
AVSC-5DA1-HDB.
• Uninstallation: Delete all the control software files in the corresponding file path.
4.4.2 Basic Settings
Connect the AVSC-5DA1-HDB to all necessary all input and output devices, then
connect it to a computer that has RS-232 control software installed. Double-click the
software icon to run this software.
Accessing through Serial
1. Using the client, select “serial” and enter “115200” for the speed (baud rate).