31
CHAPTER 4: Configuration
Figure 4-2. Unit A’s DIP switch.
ON
1 2 3 4 5 6 7 8
Top of
Unit A
Bottom of
Unit A
ON
OFF
7 & 8 both OFF:
Inactivity timeout is
2 seconds (default)
7 OFF, 8 ON:
Inactivity timeout is
10 seconds (default)
7 ON, 8 OFF:
Inactivity timeout is
30 seconds (default)
7 & 8 both ON:
Inactivity timeout is
120 seconds (2 minutes)
Position 6 OFF:
Extender sends primary CPU’s video
to both monitors (default)
Position 6 ON:
Extender sends primary CPU’s video
to monitor at most recently active
station only
Position 5 OFF:
Extender operates normally at
power-up (default)
Position 4 OFF:
Extender operates normally (default)
Position 4 ON:
Extender’s serial-mouse detection is
disabled, forcing PS/2 mouse
detection
Position 5 ON:
Extender goes into configuration
mode at power-up
Position 1 OFF:
Extender operates
normally (default)
Position 1 ON:
Extender stops operating,
does a full hardware reset
Possible Settings of
DIP-Switch Positions:
Positions 2 and 3 are reserved
for future use; leave them set to
OFF