26 • ENGLISH
Problem
Possible Causes
Solution
Pump does not reach working
pressure
Nozzle worn
Replace nozzle
Water filter fouled
Clean filter
(FIG. E16)
Water supply pressure low
Turn on water supply tap fully
Air being sucked into system
Check tightness of hose fittings
Air in pump
Switch off the appliance and keep depressing
and releasing the gun trigger until the water
comes out in a steady flow. Switch the
appliance back on again.
Adjustable nozzle not positioned correctly
Turn the adjustable nozzle
(FIG. C12)
Pressure drops during use
Water intake from external tank
Connect appliance to the mains water supply
Inlet filter dirty
Clean the inlet filter
Intake water too hot
Reduce temperature
Nozzle clogged
Clean nozzle
(FIG. E16)
Motor “sounds” but fails to start
Insufficient power supply
Check that the voltage of the mains power
supply line is the same as that on the plate
(FIG. B)
Voltage loss due to use of extension cable Check characteristics of extension cable
Appliance not used for a long period
of time
Contact your nearest Authorized Service
Centre
Problems with TSS device
Contact your nearest Authorized Service
Centre
Motor fails to start
No electrical power
Check that the plug is firmly in the socket and
that the mains voltage supply is present (*)
Problems with TSS device
Contact your nearest Authorized Service
Centre
Appliance not used for a long period of
time
Use the tool (8) to unjam the motor from the
hole at the rear of the appliance (in models with
this feature) (FIG. E16)
Water leakage
Seals worn
Have the seals replaced at your nearest
Authorized Service Centre
Appliance noisy
Water too hot
Reduce temperature (See technical data)
Oil leakage
Seals worn
Contact your nearest Authorized Service
Centre
TSS versions only: Motor starts
even with gun trigger is released
High pressure system or pump hydraulic
circuit not watertight
Contact your nearest Authorized Service
Centre
TSS versions only: No water delivery
when gun trigger is depressed
(With supply hose connected)
Nozzle clogged
Clean nozzle
(FIG. C12)
* If the motor starts and does not restart during operation, wait 2-3 minutes before repeating the start-up procedure (overload cutout
has been tripped).
If the problem recurs more than once, contact your nearest Authorized Service Centre.