Gas Pressure Fryer
Operation
22
STEP
ACTION
DISPLAY
COMMENTS
13
Repeat steps 5-12 when programming
stages 2, 3, 4 and 5 for Electric and Gas
appliance types.
Repeat steps 5-10 when programming
stages 2, 3, 4 and 5 for an ALF appliance
type.
The time and temperature of each
stage has to be less than the
preceding stage.
14
Press ENTER.
PROGRAM
PREALARM
00:00
This command allows you to
specify the number of minutes
before the end of the cooking time
(for each stage) until the alarm
sound The prealarm value
displayed may be a previously
programmed value.
15
Press TOGGLE/CLEAR and input the
prealarm minutes.
PROGRAM
PREALARM
XX:XX
XX:XX refers to the prealarm
minutes you input.
16
Press ENTER.
PROGRAM FILTER
0
This command allows you to
specify the number of fry cycles
you want to complete for this
program before a message is
displayed reminding you to filter
the shortening (filter lockout). The
filter value displayed may be a
previously programmed value.
17
Press TOGGLE/CLEAR and input the
number of fry cycles you want to
complete before enabling filter lockout.
PROGRAM FILTER
X
X refers to the number of program
cycles you want to complete
before filtering the shortening.
18
Press ENTER.
PROGRAM
PRODUCT #
19
If you wish to input more programs,
proceed by pressing the next program
number and follow steps 5 through 18 or
press PROG to exit the programming
mode.