Gas Pressure Fryer
Maintenance
27
6. Set the temperature of the solution as follows:
•
BLF-F
– Place the
FILTER/OFF/FRY
switch to the
FRY
position. Press the
START/STOP
button on
the digital timer to cancel the STIR OIL function unless the STIR OIL function is operating in the –
OFF mode.
Set the thermostat to a temperature of 190º F.
•
BLF-FC
– Position the
FILTER/OFF/FRY
switch to
ON.
Press PROG (program), type 1733, and
press ENTER. The fryer pot will heat to a temperature of 190º F during the CLEAN cycle to allow the
CLEAN function to be performed. NOTE: The fryer pot must be below 255º F to enter the CLEAN
mode.
7. Bring the cleaning solution to a rolling boil and maintain the boil for 5 minutes.
8. Place the
FILTER/OFF/FRY
switch to
OFF
.
9. Scrub the inside of the fryer pot again.
10.
Before draining the cleaning solution
,
remove the filter bag, screen and pipe connections from the filter
vat. This must be done before draining the cleaning solution.
NEVER
pump water or detergent through
the filter system.
11. After 15 minutes, slowly open the drain valve. Drain the solution into the filter vat and discard.
12. Rinse the pot with hot water, using the pot brush to remove remaining sediment, drain and discard.
13. Close the drain and refill the fryer pot with hot water to the proper level.
14.
Add approximately 4 to 6 ounces of distilled (white) vinegar to develop a neutralizing solution. Stir the
solution briefly. Leave in the pot for three to five minutes and discard.
NOTE: Foaming of shortening
after boil-outs is caused by failure to follow proper neutralizing procedures.
15. Repeat steps 12 through 14 as needed to remove all traces of cleaning solution.
16.
Rinse the pot again with Cool water, drain and discard.
Damage to the fryer could result if the fryer pot is not completely dry before filling
with shortening. Refill the fryer pot with shortening ONLY when it is completely
dry.
17. Dry the fryer pot and filter vat
COMPLETELY
.