Automatic machine parameters
Instruction manual GLM-I
266
38.019.129.001 en
20
20.9.2
Selecting polarity
For the package ejector or the dividers, the active signal level can be set accordingly. Ex-
ample: Package ejector. The procedure for dividers is analog. The following settings are
possible:
"+":
Positive logic. A signal change from 0 V to +24 V is an active
signal. Standard setting.
"-":
Negative logic. A signal change of +24 V to 0 V is an active sig-
nal.
Mode level: 5
Select polarity for package ejector.
<Automat> / <Dividers> / <Package ejector> / <Polarity pckg. eject.>
Tap the softkey until the required setting is highlighted.
Содержание GLM-I
Страница 1: ...Automatic labeler GLM I Instruction manual as of program version 11 20 menu type 1 38 019 129 001 en...
Страница 410: ...Interfaces Instruction manual GLM I 408 38 019 129 001 en 30 Illustration 76 Data transmission...
Страница 484: ...Appendix Instruction manual GLM I 38 019 129 001 en Illustration 123 Example of list 9...
Страница 486: ...Appendix Instruction manual GLM I 38 019 129 001 en Illustration 125 Example of list 14...
Страница 487: ...Instruction manual GLM I Appendix 38 019 129 001 en Overview Font set Font set Western Europe ASCII 032 127...
Страница 488: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Western Europe ASCII 144 255...
Страница 489: ...Instruction manual GLM I Appendix 38 019 129 001 en Font set Eastern Europe1 ASCII 144 255...
Страница 490: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Eastern Europe2 ASCII 144 255...
Страница 491: ...Instruction manual GLM I Appendix 38 019 129 001 en Font set Greek ASCII 144 255...
Страница 492: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Cyrillic ASCII 144 255...