Bittner Audio - Application Handbook
Page 45
This function is generally being used for impedance measurements (refer to 3.7.9.3. Line
Monitoring Seite 50).
3.7.8.2.4.
Configurations
The SXL offers the option to save up to 15 configurations. This includes all parameters of the SXL
and all devices connected to the system bus. The configurations may be labeled for easier
identification.
This page also provides status information and additional functions.
Actual SXL Configuration
Indicates the current SXL configuration and its name
Last SXL Configuration Result
Status of the last operation (save or recall of a
configuration)
Default SXL Configuration
Recalled after restart
Configuration that is re-called at the start-up of the SXL
Defined SXL Configurations
Shows the saved configurations
Default SXL Configuration
(Parameter)
Defines the start-up configuration
SXL Configuration selection by
logical inputs
This function enables the re-calling of SXL configurations
via using the logical inputs (refer to 3.7.9.1. Configuration
Switching via the Logic Inputs Seite 49)