Page 40
Bittner Audio - Application Handbook
A parameter may be changed by selecting it and pushing
ENTER.
The value will appear in
brackets, e.g.
#Standby=[ON]
. It may now be changed by using the
UP
and
DOWN
keys. If a
large value range needs to be changed (e.g. volume), holding the key down will speed it up.
Pushing
ENTER
to finalize the setting,
CANCEL
to abandon the changes.
User controllable parameters are indicated by a hash (#), e.g.
#Standby=ON
(also see section
3.7.8.1.2. Entry Modes & Status Information unterhalb).
If a connected amplifier is not featuring a certain parameter, the parameter will not be
displayed.
3.7.8.1.2.
Entry Modes & Status Information
In the first line’s right corner of the LCD, more information is displayed with 4 symbols.
Entry mode
The entry mode defines how the parameter are displayed and edited. It may be selected by
repeatedly pushing the
MODE
key:
˜
<w1>
only indicates the writable, respectively the controllable parameters (w=write).
1
means that only the currently addressed amplifier/channel may be altered.
˜
<w2>
is similar to
w1
but will also set the parameters of the associated stereo channel.
The menu items are accordingly displayed, e.g. CHAN.3+4
˜
<w*>
is
similar to
w1
but the asterisk (*) represents all amplifiers/channels. In this
mode, for example, all amplifiers may be set to standby at the same time or set mute at
the same time.
˜
<rw>
is similar to
w1
but additionally, all values, including the read only conditions are
displayed, e.g. ACStatus (= mains supply) of an amplifier, etc.
Status Information
˜
!off
The indicated device (e.g. AMP.1) is
offline
. Only valid for
AMP
,
CHAN
and
AX16
The two following Service Mode Levels are used to protect parameters from accidental changes.
˜
!sm1
Service Mode Level 1 - will be started by pushing the keys UP and DOWN at the same
time. The following parameters may then be changed:
„
Network settings (refer to 3.7.5.4. Settings of Network Parameters Seite 36)
„
Delay time when a configurations is re-called via the logic inputs (refer to 3.7.9.1.
Configuration Switching via the Logic Inputs Seite 49)
„
Continuous storage the SXL’s current condition to the intern flash disk ON/OFF(refer to
3.7.9.6. Permanent Backup of Operation Modes Seite 52)
˜
!sm2
Service Mode Level 2 – will be started by pushing the keys
UP
and
DOWN
at the same
time, followed by simultaneously pushing keys
LEFT
and
RIGHT
. The following
parameters may then be changed:
„
Manual confirmation of an error ON/OFF (refer to 3.7.9.4. Error Acknowledgment Seite
51)