14
+380 44 507 02 07
Command for deletion of all records saved –
deleterecords;
There is no response to this command. Once the command is received,
all data packets are removed from the device memory.
Set parameter values by their ID -
setparam #### #;
ID consists of 4 digits – the first digit is a profile number, the last three
specify ID of a parameter (refer to
Addendum 1
).
Command example => set the ID=0242 parameter value: setparam
0242 www.kyivstar.net;
No.
Parameter
name
Description
1
Param ID Parameter ID
2
New Value New value of a parameter
Example of a response to the "setparam 0242 www.kyivstar.net"
command - setting an APN:
Param ID 0242 New Val: www.kyivstar.net
Device firmware update -
BOOT #,#,#;
Command parameters:
HOST
– IP address of the server containing the update;
PORT
– Port of the server containing the update;
PATH
– Path to the firmware update file on the server;
Example of the command:
BOOT 213.160.136.54,88,pr/*.bin;
Where * is a version of the firmware, .bin – file format extension.
Options of response to the attempted update download:
BOOT: UPDATE DOWNLOAD OK – downloading was a success;
BOOT: WAITE ERROR – wait timeout was exceeded during update
download;
BOOT: HOST CONNECT ERROR – failed to connect to the server;
BOOT: PAGE LOAD ERROR – failed to download the file;
BOOT: UPDATE DOWNLOAD ERROR
–
failed to update the firmware;
Auto bus scan and setting available parameters
-
canobdset;
To configure the tracker you need to connect it to OBD-II diagnostic
connector, turn on the ignition and start the car engine, and send the
appropriate command to automatically scan the tire and write the
available ID data to the device.
This command can be sent in two ways: via BITREK Configurator on the
Commands tab -> Controller or by sending an SMS message
canobdset;
to the number of the SIM card installed in the tracker. After accepting the
command, the tracker sends in response a confirmation text
OBD-II
SETTINGS SET OK