background image

10 

 

 

www.bitrek.com.ua 

 

 

[email protected] 

+380 44 507 02 07

 

 

 

ATTENTION! 

Total  length  of  an  SMS  command  string 

should  not  exceed  160  Latin  characters.  Number  of 

commands  per  one  SMS  is  only  limited  by  the  maximum 
length of an SMS. 

It  is  also  essential  to  observe  the  order  of  the  commands,  when 

they  are  sent  in  one  SMS  message.  The  device  reads  and  performs  the 

commands  in  sequential  order.  E.g.,:  once  the 

cpureset;

  command  is 

received  the  device  processor  will  reset  and  the  commands  will  not  be 

further performed. 

 

Correct: 

setparam 0242 <APN>; 
setparam 0245 <HOST>; 

Incorrect: 

setparam 0246 <PORT>; 

cpureset; 
setparam 0242 <APN>; 
cpureset; 
setparam 0245 <HOST>; 
setparam 0246 <PORT>; 

 

When  login  and  passwords  pairs  are  configured  for  access  using 

SMS,  they  must  be  included  to  each  SMS  with  the  commands.  If  a 
login/password  pair  is  enabled,  but  not  included  to  an  SMS  with  the 

commands, such SMS will be ignored. If a login/password pair option is 
not enabled, it will not be checked. 

In the event that one of the authorized phone numbers is enabled, 

SMS  commands  will  only  be  performed  provided  that  they  have  been 

sent from one of the authorized phone numbers (login/password is also 
required,  if  enabled).  If  there  is  no  authorized  phone  number  enabled, 

SMS with commands will be received from any phone number.  

 

Configuring the Device 

 

The BI-820OBD TREK Tracking Device can be configured by one of 

the methods below: 

 

1. Using a direct connection between the device and a computer. 
2. Remotely, using SMS commands. 
 
Configuration  of  the  device  by  any  of  the  methods  available  only 

requires  configuring  necessary  device  parameters.  Each  parameter  has 

its own unique ID. Special commands are used to read/record the values 
of a selected parameter. 

In  case  of  remote  configuration  of  the  device  using  SMS,  one 

should  bear  in  mind  that  the  total  length  of  an  SMS  should  not  exceed 

160 Latin characters. Number of commands per one SMS is only limited 
by the maximum length of an SMS. 

All  commands  for  device  manipulation  can  be  divided  into  the 

controlling and information ones. 

 
 
 

Содержание BI-820OBD TREK

Страница 1: ...rek com ua sales bitrek com ua 380 44 507 02 07 95 C Otradny Prospekt Kiev 03061 Ukraine phone 38044 507 02 07 fax 038044 507 02 02 www bitrek com ua sales bitrek com ua Phone 38044 507 02 07 Fax 38044 507 02 02 www bitrek com ua sales bitrek com ua Vehicles Tracking Device BI 820OBD TREK Operating Manual Version 2018 11 1 ...

Страница 2: ...ent 7 Installation and Commissioning 7 Installation Guide 7 Connection to a Computer 8 Indicators Description 9 List of SMS Commands 9 Structure of the SMS Commands 9 Configuring the Device 10 Detailed Description of Information Commands 12 Detailed Description of Controlling Commands 13 Basic Device Configuration 15 Security Settings 15 Configuring I O Components 16 Configuring Alarms 20 Descript...

Страница 3: ...abels must be observed Warranty The warranty period for the tracking device shall be 12 months of the date of commissioning The commissioning date must be recorded per requirements set forth in the certificate for the tracking device if no such data are available in the certificate the warranty period shall be counted starting with the tracking device shipment to the customer Manufacturer s warran...

Страница 4: ...rocesses information from the on board computer of the car The data obtained are recorded and stored in the internal log that is based on a non volatile memory chip Records from this log are transferred to the operator panel through a GSM channel with a predetermined frequency or on an event basis Information exchange is done via GPRS and SMS Voice communication is also supported On line terminal ...

Страница 5: ...an European Chrysler vehicles Voltage 12 V or 24 V Normal input current 12 V 60 mA Max current 12 V 350 mА Non volatile memory capacity 2 MB 65 000 records Internal battery Li Ion 1 000 mАh Operating temperature От 30 С до 80 С Dimensions W х L х H 85 х 95 х 33 mm Weight 200 gr Housing protection class IP65 Tracking device design Fig 1 Appearance and Dimensions of Tracking Device BI 820OBD TREK ...

Страница 6: ...ce Contacts of the SIM card must not be saved PIN code must be disabled a SIM card with an enabled PIN code can be used provided that the PIN code has been entered into the device settings To insert a SIM card all device connectors must be disconnected and its top cover must be removed There is a slot on the top of the circuit board Then the device has to be reassembled in the reversed order ATTEN...

Страница 7: ... H Input Output CAN_H signal J 2284 7 K Line Input Output Data transmission reception line SAE 14 CAN L Input Output CAN_L signal J 2284 15 Line ISO Input Output Diagnostic line SAE 16 Vin Power on board power terminal nominal voltage is 12 VDC or 24 VDC Installation and Commissioning Installation Guide Tracking device location must ensure connections of OBD II sockets and avoid potential of accid...

Страница 8: ...n Fig 3 BI 820OBD TREK Connection Diagram A terminal program can be used for data exchange with the device Terminal configuration settings bit rate 115 200 bps data bit 8 stop bit 1 without parity check without stream control Once the link is up the device will start sending its status data to the terminal Using the terminal program a user can send commands to the device and receive responses to t...

Страница 9: ...seconds Satellites are available coordinates have been established List of SMS Commands SMS commands are used for getting current state of the device troubleshooting potential errors configuring the settings etc An SMS command should be sent together with login and password the sender s number must be included to the list of authorized contacts when such list is used Structure of the SMS Commands ...

Страница 10: ...n is not enabled it will not be checked In the event that one of the authorized phone numbers is enabled SMS commands will only be performed provided that they have been sent from one of the authorized phone numbers login password is also required if enabled If there is no authorized phone number enabled SMS with commands will be received from any phone number Configuring the Device The BI 820OBD ...

Страница 11: ...o Getting the readings from internal device sensors yes 6 flush Request for device profile parameters yes 7 getparam Get a parameter by its ID yes Table 4 List of Controlling Commands No Command Description Response 1 cpureset Reset of the device CPU none 2 rstallprof Reset to default profile parameters none 3 deleterecords Deletion of all records saved none 4 setparam Set a parameter by its ID ye...

Страница 12: ...rk Example of a response Data Link 1 GPRS 1 IP 46 133 143 201 GSM 5 Roaming 0 Retrieval of current location of the device getstatus No Parameter name Description 1 GPS Valid data 1 Invalid data 0 2 Sat Number of visible satellites 3 Lat Latitude previous known latitude 4 Long Longitude previous known longitude 5 Alt Altitude m 6 Speed Speed km h 7 Dir Direction degrees 8 Date Date 9 Time Current G...

Страница 13: ...parameter ID getparam ID consists of 4 digits the first digit is a profile number the last three specify ID of a parameter Command example request value of ID 0242 parameter getparam 0242 No Parameter name Description 1 Param ID Parameter ID 2 Value Parameter value Example of a response to the getparam 0242 command Param ID 0242 Val internet Detailed Description of Controlling Commands Command of ...

Страница 14: ...he server Example of the command BOOT 213 160 136 54 88 pr bin Where is a version of the firmware bin file format extension Options of response to the attempted update download BOOT UPDATE DOWNLOAD OK downloading was a success BOOT WAITE ERROR wait timeout was exceeded during update download BOOT HOST CONNECT ERROR failed to connect to the server BOOT PAGE LOAD ERROR failed to download the file BO...

Страница 15: ...operation of the device include data transfer and tracking settings They are included to the Server GPRS and Tracking groups Once the appropriate settings are configured the device will start transmitting the data of its current location to the server All configurable settings are given in Addendum 1 Security Settings To comply with the security regulations access to the device configuration setti...

Страница 16: ... SMS from the authorized phone numbers saved to its memory If SMS login and password are enabled they must be included in each SMS with the commands Configuring I O Components The BI 820OBD TREK Tracking Device can collect process and send data obtained from different sensors to the server Each sensor is an I O component and has a group consisting of 6 parameters for configuration E g to configure...

Страница 17: ... 5 monitoring going beyond range 6 monitoring going within beyond range 7 event generation by change of an input by a preset value 8 event generation by change of an input by a preset value monitoring 5 Averaging constant 0 Clarifications to Table 5 Parameter 0 enabling disabling I O component transmission to the server Parameter 1 Priority low high When selecting the Priority low option the data ...

Страница 18: ...nsor readings comes within such configured range In all other cases the event will not be generated and no information will be sent to the server Example Lower threshold of input voltage is set to 0 V the upper threshold is 10 V 10000 mV If the input voltage decreases lower than 10 V the event will be generated Figure 4 Fig 4 Generation of the Event by Going Within Range 1 Going beyond range An ev...

Страница 19: ...set to 5 V 5 000 and the upper threshold is 10 V 10 000 mV When actual input voltage goes off the limits of a configured range the event is generated Figure 6 Fig 6 Generation of the Event by Going Within Beyond Range 3 Monitoring When this mode is selected the data will be transmitted continuously and no events will be generated 4 Monitoring Going Within Range When a Going Within Range event is g...

Страница 20: ... The list of all I O components of the device available for configuration is given in Addendum 2 Configuring Alarms The device can be configured so as to make an outbound call if a particular condition is met Activation of a particular I O component constitutes such condition Voice calls must be enabled in general configuration settings of the device I O component must be enabled configured to one...

Страница 21: ...imeout or it has been detected but has failed to register on the network the device puts the modem to the sleep for a particular timeout Once such timeout is reached the process is repeated Mode 1 Operator Selection Enable ID 0917 1 In this mode the device tries to register on the enabled network set by the entire list of enabled networks parameters ID 0020 0059 If the SIM card is detected and rea...

Страница 22: ... 0060 0099 string List of APNs of enabled carriers 2 UsLoginTable 0100 0139 string List of GPRS logins of enabled carriers 3 UsPassTable 0140 0179 string List of GPRS passwords of enabled carriers Specify APNs of enabled networks setparam 0060 APN setparam 0061 APN setparam 0099 APN Specify GPRS logins of enabled networks setparam 0100 GPRS login setparam 0101 GPRS login setparam 0139 GPRS login S...

Страница 23: ... by default is set to 0 If 0196 is set to 0 only Host1 and Port1 are used If 0196 is set to 1 the device at first tries to connect to Host1 and Port1 several times If it fails then the device tries to connect to a backup server Host2 Port2 when a configured timeout is reached Configuration example Enabling the use of a backup server setparam 0196 1 IP Host2 setparam 0188 111 1 111 11 Port2 setpara...

Страница 24: ...st1 0188 none String Backup server IP address none IP or DNS 31 28 163 20 ipsPort1 0189 none 2 Byte Backup server PORT none PORT 20127 APN 0242 none String GPRS access point none APN gps utel ua Usname 0243 none String GPRS access login none User Name none Uspass 0244 none String GPRS access password none User Password none Send Period 0270 none 2 byte Transmission to server time sec 0 65535 60 Co...

Страница 25: ...etrieval with the ignition on sec 0 65535 30 Night Period 0011 none 2 byte Enabling time of retrieval with the ignition off sec 0 65535 30 Dist Period 0012 none 2 byte Retrieval period by distance meters 0 65535 500 Angle Period 0013 none 1 byte Retrieval period by azimuth degrees 1 180 10 Record Amount 0232 none 2 byte Number of records per packet pcs 0 65535 0 Delta X 0281 none 1 byte Accelerati...

Страница 26: ...0 Wait Sleep TM 4007 none 2 byte Timeout for sleep by acceleration meter minutes 5 65535 15 Sleep TM 4008 none 2 byte Sleep timeout by acceleration meter minutes 0 65535 720 Min GPS speed 0918 none 1 byte Minimum speed according to GPS for movement detection km h 1 256 5 GPS Source Select 4016 none 1 byte Selecting geopositioning system c u 0 or 3 GPS GLONASS 1 GPS only 2 GLONASS only 3 Safety Pho...

Страница 27: ... 0267 none String Authorized phone number 6 xxxxxxxxxxxx Phone7 0268 none String Authorized phone number 7 xxxxxxxxxxxx Phone8 0269 none String Authorized phone number 8 xxxxxxxxxxxx SMS Login 0252 none String SMS access login Login SMS Password 0253 none String SMS access password Password Terminal Password 0910 none String Device access password 11111 SIM_PIN 0818 none 1 byte Enabling SIM card c...

Страница 28: ...ive 0907 none 2 byte GPRS session lifetime min 1 65535 480 Voice communication Input Call Trigger 0994 none 1 byte Response to incoming call with digital inputs 0 disabled 1 6 ID of I O component digital input used for response to incoming call 0 RingNum 0912 none 1 byte Number of rings prior to auto phone pickup pcs 1 256 3 Alarms RingEnable 0913 none 1 byte Enabling outbound voice calls 0 disabl...

Страница 29: ...D of I O component triggering SMS to be sent to an authorized phone number in cases of event generation ID SMSText 0817 none String Text added to SMS NMT 30 Latin characters Text Roaming Operator Selection Enable 0917 none 1 byte Enabling carrier selection 0 disabled 1 enabled 0 UsIpTable 0020 0059 none String List of enabled carriers xxxxx UsAPNTable 0060 0099 none String List of APNs of enabled ...

Страница 30: ...Table 0100 0139 none String List of GPRS logins of enabled carriers Login UsPassTable 0140 0179 none String List of GPRS passwords of enabled carriers Password Parameters for I O Component Configuration CAN_Baud 0216 none 1 byte CAN BUS baud rate Kbit s 0 125000 1 250000 2 500000 3 autobaud 4 33333 5 50000 6 83000 7 83333 8 100000 3 Fuel_type 4011 Нет 1 byte Fuel type 0 gasoline 1 diesel 0 ...

Страница 31: ... Movement status none 0 no movement 1 movement VBAT 0420 0425 67 2 byte Battery voltage V PSV 0410 0415 66 2 byte Power supply voltage V GPSSpeed 0490 0495 24 2 byte Speed per GPS km h GPSPower 0450 0455 69 1 byte Availability of GPS signal pcs 0 disabled 1 enabled pcbTemp 0440 0445 70 4 byte Device temperature C realOdometr 0500 0505 199 4 byte Relative virtual odometer km Odometr 0710 0715 200 4...

Страница 32: ...s missi on Bit depth Parameter purpose Units Possible values Default values modemStat 0750 0755 117 1 byte Transmission of device modem status none 0 not active 1 active SIM_Stat 0790 0795 121 1 byte SIM card status none 0 no SIM detected 1 SIM detected 2 SIM detected but not ready 3 SIM detected and ready ...

Страница 33: ...twork registration status none 0 not registered and not searching for carriers 1 home network 2 not registered but searching for carriers 3 registration disabled 4 status unknown 5 roaming GPRS_net Stat 0770 0775 119 1 byte GPRS network registration status none 0 not registered and not searching for carriers 1 home network 2 not registered but searching for carriers 3 registration disabled 4 statu...

Страница 34: ...ving 5000 5005 190 4 byte Device operation time minutes axesX 0720 0725 114 1 byte Actual value of X direction elevation angle degrees 0 255 axesY 0730 0735 115 1 byte Actual value of Y direction elevation angle degrees 0 255 axesZ 0740 0745 116 1 byte Actual value of Z direction elevation angle degrees 0 255 HDOP 0800 0805 122 2 byte Horizontal accuracy determination c u 0 9999 CAN KLINE 3320 332...

Страница 35: ...scription Calculating formula Units 6 Ignition status A 170 Calculated engine load value A 100 255 171 Engine coolant temperature A 40 C 172 Intake manifold absolute pressure A kPa 173 Vehicle speed A km h 174 Intake air temperature A 40 C 176 Fuel level A 100 255 177 Barometric pressure A kPa 178 Ambient air temperature A 40 C ...

Страница 36: ...0 255 180 Accelerator pedal position E A 100 255 181 Accelerator pedal position F A 100 255 182 Relative accelerator pedal position A 100 255 183 Hybrid battery pack remaining life A 100 255 184 Engine oil temperature A 40 C 210 Engine RPM A 4 rpm 211 Run time since engine start A seconds 212 Distance traveled with malfunction indicator lamp MIL on A km ...

Страница 37: ...lating formula Units 213 Distance traveled since codes cleared A km 214 Absolute load value A 100 255 215 MAF air flow rate A 100 grams sec 216 Time since trouble codes cleared A minutes 217 Engine fuel rate A 0 05 L h 219 Odometer A km 220 VSS Odometer A km 221 MAF fuel consumption rate A 0 1 L ...

Страница 38: ...38 www bitrek com ua sales bitrek com ua 380 44 507 02 07 Document version Date Version Note 12 06 2018 Ver 2018 06 1 Basic document 09 07 2018 Ver 2018 11 1 Changed the firmware update port number ...

Отзывы: