34
www.bitrek.com.ua
[email protected]
+380 44 507 02 07
Parameter
name
ID for
configu
ration
ID
for
trans
missi
on
Bit
depth
Parameter purpose
Units
Possible values
Default
values
MIN_durati
on_of_fuel
0349
none
1 byte
Filter of digital input dlow3.
Levels below the specified
one will be filtered
10 mS
1 - 20
5
ValidFuel
Level
0819
none
1 byte
Enabling the use of last
valid fuel level (filtered and
non-filtered levels)
none
0 - disabled; 1 -
enabled;
0
polling_
period_fuel
0197
none
2 byte
Polling period for four
RS485-based fuel meters
0.1
sec.
-
100
polling_
period_RFID
0198
none
2 byte
Polling period for RS485-
based RFID
0.1
sec.
-
15
polling_
period_radio
module
0199
none
2 byte
Polling period of RS485-
based wireless sensor of
tailing equipment
0.1
sec.
-
100
polling_
period_RFID
_RKS
0201
none
2 byte
Polling period for RS485
RFID RKS (SOVA)
0.1
sec.
-
15
FactorF
0950
none
4 byte
F factor for Kalman filter
c.u.
-
1000000