31
IgnInput
5006
string
Software switching of the
ignition between the
discrete inputs (1 - DAThigh
1, 2- DAThigh 2)
-
1
Name of
parameter
ID at
configurati
on
Grade of
parameter
Parameter purpose
Measureme
nt unit
Default value
AIN1
0957
2 byte
Kalman rate for the analog
input No. 1 filtering (1 - off;
filtration range is 2 - 65535)
c.u.
19
AIN2
0958
2 byte
Kalman rate for the analog
input No. 2 filtering (1 - off;
filtration range is 2 - 65535)
c.u.
19
ValidFuelLevel
0819
1 byte
Permission to use the last
valid level of fuel level
-
0
Polling_period_
fuel
0197
1 byte
Polling period for 4 fuel level
sensors
100 ms
100
Factor F
0950
4 byte
F coefficient for Kalman
filter
c.u.
1000000
Factor Q
0951
4 byte
Q coefficient for Kalman
filter
c.u.
1000000
Factor H
0952
4 byte
H coefficient for Kalman
filter
c.u.
1000000
Factor Rs
0953
4 byte
R coefficient for Kalman
filter at motion absence
c.u.
20000000
Factor Rm
0954
4 byte
R coefficient for Kalman
filter at motion
c.u.
400000000