17
To set the login and password, any SMS command shall have the
following structure to be sent:
<Login><Password><Command1>;<Command2>;<Command3>;
Example of the command to be sent: abcd 1234 getgps; getstatus;
In addition to the login and password, use the authorized phone
numbers. To record the telephone numbers in the memory device use the
parameters ID 0261 - ID 0269 (
Appendix 1
). Total up to 8 phone numbers
can be applied. When using this function, the device will respond to SMS
from the stored in the memory authorized phone numbers only.
If the login and password are set by SMS, they shall be specified in
each SMS with commands.
Adjustment of I/O elements
The tracking device "BI 530R TREK" is able to collect, process and
send to the server the data received from various sensors. Each sensor is
an I/O element and has a group consisting of 6 parameters for setting. For
example, to set the value of power supply voltage level to the server, use
group of parameters of ID 0410/0411/0412/0413/0414/0415. These
options have the following structure:
0410/0411/0412/0413/0414/0415
First 3 numbers (green) refer to parameter group number to
configure the I/O element.
Last
number
(grey)
is
a
parameter
number.
6 parameters (from 0 to 5) are available for a single I/O element. Possible
values of these parameters are presented in Table 5.
Table 5 - List of parameters of I/O elements
Parameter
number
Description
Possible values
0
Enable/disable I/O
element
0 - disabled; 1 - enabled
1
Priority of I/O
element at
transmission
0 - low; 1 - high
2
Upper limit
(depending on the type of I/O
element)
3
Lower limit
(depending on the type of I/O
element)
4
Setting of the type of
the generated event
0 - entering the range;
1 - leaving the range;
2 - returning/leaving to/of the
range;
3 - monitoring;